Photon dose calculation of a three‐dimensional treatment planning system compared to the Monte Carlo code BEAM
- 11 July 2000
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 27 (7), 1579-1587
- https://doi.org/10.1118/1.599024
Abstract
The purpose of this work is to compare the photon dose calculation of a commercially available three-dimensional (3D) treatment planning system based on the collapsed cone convolution technique against BEAM, a Monte Carlo code that allows detailed simulation of a radiotherapy accelerator. The first part of the work is devoted to the commissioning of BEAM for a 6 MV photon beam and to the optimization of the linac description to fit the experimental data. This step also involves a comparison with radiochromic film data on an inhomogeneous phantom built to simulate electronic nonequilibrium conditions. Commissioning the selected photon beams required a careful description of the treatment head and the fine tuning of physical parameters such as electron beam energy and radius. The second part shows the dose comparison for real patient's CT data sets: A mediastinal treatment and a breast treatment were simulated. Doses in terms of absolute values per monitor unit were calculated based on the BEAM simulation of the CT data sets. For comparisons of real-patient cases, differences between the treatment planning system and BEAM ranged from 0 to 2.6% and were within +/-2 standard deviations for the dose calculated at the prescription point. Dose-volume histogram analysis indicated that there is no consistent difference between the Monte Carlo and the convolution calculations. On the basis of the results presented in this study, we can conclude that the CCC algorithm is capable of giving results absolutely comparable to those of a Monte Carlo calculation, as far as common 3D radiotherapy planning is concerned.Keywords
This publication has 28 references indexed in Scilit:
- Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55Medical Physics, 1998
- Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam modelMedical Physics, 1997
- Accurate characterization of Monte Carlo calculated electron beams for radiotherapyMedical Physics, 1997
- Effect of low-density lateral interfaces on soft-tissue dosesInternational Journal of Radiation Oncology*Biology*Physics, 1997
- The influence of air cavities on interface doses for photon beamsInternational Journal of Radiation Oncology*Biology*Physics, 1993
- 3D dose calculations for electron and photon beamsPhysics in Medicine & Biology, 1992
- Monte Carlo Techniques of Electron and Photon Transport for Radiation DosimetryPublished by Elsevier ,1990
- Calculation and Application of Point Spread Functions for Treatment Planning with High Energy Photon BeamsActa Oncologica, 1987
- Underdosing of lesions resulting from lack of electronic equilibrium in upper respiratory air cavities irradiated by 10 mv X-ray beamsInternational Journal of Radiation Oncology*Biology*Physics, 1977
- Dosimetry at Interfaces for High Energy X and Gamma RaysThe British Journal of Radiology, 1966