A Biomechanical Comparison of Initial Soft Tissue Tibial Fixation Devices
- 1 June 2004
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 32 (4), 956-961
- https://doi.org/10.1177/0363546503261696
Abstract
Background: Biomechanical testing of the Intrafix device has not been performed using human tibiae. Hypothesis: The Intrafix device would provide comparable or superior tibial fixation of a quadrupled hamstring tendon graft to a 35-mm-long bioabsorbable interference screw. Study Design: In vitro, biomechanical study. Methods: Eight paired human tibiae and 16 quadrupled hamstring tendon grafts were divided into 2 groups. Each quadrupled hamstring tendon graft was fixed in a tunnel sized to 0.5 mm graft diameter with either an Intrafix device or a screw. Results: Displacement at failure was greater in the Intrafix group (17.3 ± 4.6 mm versus 10.9 ± 4.4 mm, P = .002). Load at failure (796 ± 193 N versus 647 ± 269 N), stiffness (49.2 ± 21.9 N/mm versus 64.5 ± 22 N/mm), and bone mineral density (0.74 ±0.15 gm/cm3 versus 0.74 ± 0.14 gm/cm3) did not display significant differences for the Intrafix device and the screw, respectively (P > .05). Conclusions: Displacement at failure was greater for the Intrafix device. Clinical Relevance: Increased displacement at failure for the Intrafix group suggests slippage from sheath channel deployment. Concentric fixation may not occur when less than optimal tibial bone mineral density increases the difficulty of attaining precise sheath deployment and quadrupled hamstring tendon graft strand alignment.Keywords
This publication has 14 references indexed in Scilit:
- The Fixation Strength of Six Hamstring Tendon Graft Fixation Devices in Anterior Cruciate Ligament Reconstruction: Part II: Tibial SiteThe American Journal of Sports Medicine, 2003
- Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniquesArthroscopy: The Journal of Arthroscopic & Related Surgery, 2002
- Effect of Screw Length on Bioabsorbable Interference Screw Fixation in a Tibial Bone TunnelThe American Journal of Sports Medicine, 2001
- Technical note: Alternative soft-tissue graft preparation technique for cruciate ligament reconstructionArthroscopy: The Journal of Arthroscopic & Related Surgery, 2000
- Graft Fixation in Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2000
- Interference Screw Fixation Strength of a Quadrupled Hamstring Tendon Graft Is Directly Related to Bone Mineral Density and Insertion TorqueThe American Journal of Sports Medicine, 2000
- Comparison of eccentric and concentric screw placement for hamstring graft fixation in the tibial tunnelKnee Surgery, Sports Traumatology, Arthroscopy, 2000
- Structural Properties of Six Tibial Fixation Methods for Anterior Cruciate Ligament Soft Tissue GraftsThe American Journal of Sports Medicine, 1999
- Revision Anterior Cruciate Ligament Surgery: Experience From MiamiClinical Orthopaedics and Related Research, 1996
- Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction: Brief reportArthroscopy: The Journal of Arthroscopic & Related Surgery, 1989