THE UREA CLEARANCE OF RATS: ITS TECHNIQUE AND NORMAL RANGE

Abstract
A method is descr. for determining urea clearance of rat^s. Urea clearances on normal rats, on a milk diet, detd. in the manner described, showed a mean average of 10.9 cc. per sq. m. of body surface per min. The standard deviation was [plus or minus] 3.1 cc.