A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Top Cited Papers
- 8 March 2007
- journal article
- research article
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 356 (10), 989-997
- https://doi.org/10.1056/nejmoa066633
Abstract
Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been questioned recently. We performed a pooled analysis of 1748 patients in four randomized trials evaluating the safety of sirolimus-eluting stents as compared with bare-metal stents. Patient-level data were obtained and analyzed by independent statisticians at two academic institutions. The primary safety end point was survival at 4 years. We tested for heterogeneities in treatment effect in patient subgroups. The survival rate at 4 years was 93.3% in the sirolimus-stent group, as compared with 94.6% in the bare-metal–stent group (hazard ratio for death, 1.24; 95% confidence interval [CI], 0.84 to 1.83; P=0.28). In the 428 patients with diabetes, a significant difference in the survival rate was observed in favor of the bare-metal–stent group over the sirolimus-stent group (95.6% vs. 87.8%; hazard ratio for death in the sirolimus-stent group, 2.9; 95% CI, 1.38 to 6.10; P=0.008). The lower survival rate among patients with diabetes who were treated with sirolimus-eluting stents was due to increased numbers of deaths from both cardiovascular and noncardiovascular causes. No difference in survival rate was detected among the patients without diabetes. Rates of myocardial infarction and stent thrombosis were similar in the two groups. In a pooled analysis of data from four trials comparing sirolimus-eluting stents and bare-metal stents, no significant differences were found between the two treatments in rates of death, myocardial infarction, or stent thrombosis. (ClinicalTrials.gov numbers, NCT00233805, NCT00381420, NCT00232765, and NCT00235144.)Keywords
This publication has 20 references indexed in Scilit:
- Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysisEuropean Heart Journal, 2006
- Three-Year Clinical Follow-Up of the Unrestricted Use of Sirolimus-Eluting Stents as Part of the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) RegistryThe American Journal of Cardiology, 2006
- Pathology of Drug-Eluting Stents in HumansJournal of the American College of Cardiology, 2006
- Safety of Coronary Sirolimus-Eluting Stents in Daily Clinical PracticeCirculation, 2006
- Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapyThe Lancet, 2004
- The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS)Journal of the American College of Cardiology, 2004
- Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting StentCirculation, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS)The Lancet, 2003
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002