A programmable system for acquisition and reduction of respiratory physiological data
- 1 January 1989
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 17 (1), 93-108
- https://doi.org/10.1007/bf02364275
Abstract
A portable software package (TIDAL—Tools for Intelligent Data Acqusition in the Laboratory) for acquiring and analyzing respiratory physiological data is described. TIDAL supports flow-, volume-, and concentration-measuring devices, and any other instruments that produce linear analog outputs. The system allows users to specify the names and types of channels to be sampled, and the calculations involved in reducing samples to breath-to-breath values. The specification of channels and calculations is given in EDL, and Experiment Description Language designed for respiratory physiology. EDL comprises a set of internal functions (primitives) which can be combined into arbitrarily complex expressions. To simplify EDL programming, TIDAL includes a macro processor and a standard macro library; the library contains definitions for a wide variety of respiratory variables. Examples are inspiratory and expiratory times and total volumes, mean inspired and expired gas volumes and concentrations, and end-tidal concentrations. Variables that are derived from these primary data, such as respiratory quotient, are also easily specified. TIDAL is written entirely in the C programming language, with special attention to portable coding practices. The code is organized in a modular structure that eases porting to multiple hardware/compiler/operating system environments.Keywords
This publication has 9 references indexed in Scilit:
- On-line computer estimation of carbon dioxide response curvesJournal of Clinical Monitoring and Computing, 1986
- A microprocessor-based system for measurement of gas exchangeJournal of Medical Systems, 1984
- A computerized mass spectrometer and flowmeter system for respiratory gas measurementsAnnals of Biomedical Engineering, 1983
- Breath-by-breath measurement of true alveolar gas exchangeJournal of Applied Physiology, 1981
- Sensitivity of Breath-to-Breath Gas Exchange Measurements to Expiratory Flow ErrorsIEEE Transactions on Biomedical Engineering, 1981
- Breath-by-breath variation of FRC: effect on VO2 and VCO2 measured at the mouthJournal of Applied Physiology, 1979
- Computer-based system for analysis of respiratory responses to exerciseJournal of Applied Physiology, 1977
- On-line computer analysis and breath-by-breath graphical display of exercise function tests.Journal of Applied Physiology, 1973