Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
Top Cited Papers
Open Access
- 31 July 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (2), 297-305
- https://doi.org/10.1002/mrm.10212
Abstract
Time-resolved contrast-enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The variable density k-space sampling intrinsic to this sequence is combined with temporal k-space interpolation to provide time frames as short as 4 s. This time resolution reduces the need for exact contrast timing while also providing dynamic information. Spatial resolution is determined primarily by the projection readout resolution and is thus isotropic across the FOV, which is also isotropic. Although undersampling the outer regions of k-space introduces aliased energy into the image, which may compromise resolution, this is not a limiting factor in high-contrast applications such as MRA. Results from phantom and volunteer studies are presented demonstrating isotropic resolution, broad coverage with an isotropic field of view (FOV), minimal projection reconstruction artifacts, and temporal information. In one application, a single breath-hold exam covering the entire pulmonary vasculature generates high-resolution, isotropic imaging volumes depicting the bolus passage. Magn Reson Med 48:297–305, 2002.Keywords
This publication has 28 references indexed in Scilit:
- Dynamic 3D MR angiography of the pulmonary arteries in under four secondsJournal of Magnetic Resonance Imaging, 2001
- 3D Time‐resolved contrast‐enhanced MR DSA: Advantages and tradeoffsMagnetic Resonance in Medicine, 1998
- Three‐dimensional projection imaging with half the number of projectionsMagnetic Resonance in Medicine, 1997
- Effects of polar sampling in k‐spaceMagnetic Resonance in Medicine, 1996
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991
- MR fluoroscopy: Technical feasibilityMagnetic Resonance in Medicine, 1988
- Experimental simulation evaluation of ECG‐gated heart scans with a small number of viewsMedical Physics, 1983
- True three-dimensional image reconstruction by nuclear magnetic resonance zeugmatographyPhysics in Medicine & Biology, 1981