Two‐point water‐fat imaging with partially‐opposed‐phase (POP) acquisition: An asymmetric Dixon method
Open Access
- 7 August 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (3), 572-584
- https://doi.org/10.1002/mrm.20984
Abstract
A novel two-point water-fat imaging method is introduced. In addition to the in-phase acquisition, water and fat magnetization vectors are sampled at partially-opposed-phase (POP) rather than exactly antiparallel as in the original Dixon method. This asymmetric sampling encodes more valuable phase information for identifying water and fat. From the magnitudes of the two complex images, a big and a small chemical component are first robustly obtained pixel by pixel and then used to form two possible error phasor candidates. The true error phasor is extracted from the two error phasor candidates through a simple procedure of regional iterative phasor extraction (RIPE). Finally, least-squares solutions of water and fat are obtained after the extracted error phasor is smoothed and removed from the complex images. For noise behavior, the effective number of signal averages NSA* is typically in the range of 1.87–1.96, very close to the maximum possible value of 2. Compared to earlier approaches, the proposed method is more efficient in data acquisition and straightforward in processing, and the final results are more robust. At both 1.5T and 0.3T, well separated and identified in vivo water and fat images covering a broad range of anatomical regions have been obtained, supporting the clinical utility of the method. Magn Reson Med, 2006.Keywords
This publication has 26 references indexed in Scilit:
- Field map estimation with a region growing scheme for iterative 3‐point water‐fat decompositionMagnetic Resonance in Medicine, 2005
- Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithmMagnetic Resonance in Medicine, 2004
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003
- Understanding phase maps in MRI: a new cutline phase unwrapping methodIEEE Transactions on Medical Imaging, 2002
- Inversion recovery image reconstruction with multiseed region-growing spin reversalJournal of Magnetic Resonance Imaging, 1996
- Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon techniqueJournal of Magnetic Resonance Imaging, 1995
- Multipoint dixon technique for water and fat proton and susceptibility imagingJournal of Magnetic Resonance Imaging, 1991
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Proton MR Chemical Shift Imaging using Double and Triple Phase Contrast Acquisition MethodsJournal of Computer Assisted Tomography, 1989
- An Introduction to the Ising ModelThe American Mathematical Monthly, 1987