Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Top Cited Papers
Open Access
- 29 December 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (1), 35-45
- https://doi.org/10.1002/mrm.10675
Abstract
This work describes a new approach to multipoint Dixon fat–water separation that is amenable to pulse sequences that require short echo time (TE) increments, such as steady‐state free precession (SSFP) and fast spin‐echo (FSE) imaging. Using an iterative linear least‐squares method that decomposes water and fat images from source images acquired at short TE increments, images with a high signal‐to‐noise ratio (SNR) and uniform separation of water and fat are obtained. This algorithm extends to multicoil reconstruction with minimal additional complexity. Examples of single‐ and multicoil fat–water decompositions are shown from source images acquired at both 1.5T and 3.0T. Examples in the knee, ankle, pelvis, abdomen, and heart are shown, using FSE, SSFP, and spoiled gradient‐echo (SPGR) pulse sequences. The algorithm was applied to systems with multiple chemical species, and an example of water–fat–silicone separation is shown. An analysis of the noise performance of this method is described, and methods to improve noise performance through multicoil acquisition and field map smoothing are discussed. Magn Reson Med 51:35–45, 2004.Keywords
This publication has 24 references indexed in Scilit:
- Magnetization preparation during the steady state: Fat‐saturated 3D TrueFISPMagnetic Resonance in Medicine, 2001
- Linear combination steady-state free precession MRIMagnetic Resonance in Medicine, 2000
- Fluctuating equilibrium MRIMagnetic Resonance in Medicine, 1999
- Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon techniqueJournal of Magnetic Resonance Imaging, 1995
- Multipoint dixon technique for water and fat proton and susceptibility imagingJournal of Magnetic Resonance Imaging, 1991
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.Radiology, 1990
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990
- Steady-State Magnetizations in Rapid NMR Imaging Using Small Flip Angles and Short Repetition IntervalsIEEE Transactions on Medical Imaging, 1987
- Simple proton spectroscopic imaging.Radiology, 1984