Randomized study of the safety and clinical utility of rotational angiography versus standard angiography in the diagnosis of coronary artery disease
- 21 May 2004
- journal article
- clinical trial
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 62 (2), 167-174
- https://doi.org/10.1002/ccd.20036
Abstract
This study evaluates the safety and clinical utility of rotational angiography in the diagnosis of coronary artery disease. High‐speed rotational angiography is a newly available angiographic modality that gives a dynamic multiple‐angle perspective of the coronary tree during a single contrast injection. We prospectively randomized 56 patients referred for diagnostic coronary angiography to either standard or rotational angiography. Contrast and radiation utilization were compared between the two groups. The number of additional cine acquisitions needed was used to determine adequacy of the diagnostic study protocol. Rotational angiography was successfully completed in all subjects. There was a 33% reduction in contrast utilization in the rotational group as compared to the standard group (35.6 ± 12.6 vs. 52.8 ± 10.7 ml, respectively; P < 0.0001). Additionally, there was a 28% reduction in total radiation exposure in the rotational group as compared to the standard group (39.0 ± 18.5 vs. 53.9 ± 23.4 Gycm2, respectively; P = 0.01). Total whole‐body radiation exposure to the primary operator was 144 mrem with rotational angiography and 170 mrem with standard angiography. Procedure time tended to be shorter for rotational angiography (353.9 ± 146.7 vs. 396.8 ± 165.8 s; P = 0.3). Rotational coronary angiography can be rapidly performed in any patient and provides a significant reduction in contrast and radiation utilization while at the same time providing adequate angiographic data to complement or replace standard coronary angiography in the evaluation of coronary artery disease. Catheter Cardiovasc Interv 2004;62:167–174.Keywords
This publication has 12 references indexed in Scilit:
- Usefulness of rotational spin for coronary angiography in patients with advanced renal insufficiencyThe American Journal of Cardiology, 2002
- Magnitude and consequences of error in coronary angiography interpretation (the ACRE study)The American Journal of Cardiology, 2000
- Effect of variability in the interpretation of coronary angiograms on the appropriateness of use of coronary revascularization proceduresAmerican Heart Journal, 2000
- Atherosclerosis in angiographically “normal” coronary artery reference segments: An intravascular ultrasound study with clinical correlationsJournal of the American College of Cardiology, 1995
- Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteriesAmerican Heart Journal, 1994
- Accuracy and precision of quantitative digital coronary arteriography: Observer‐, short‐, and medium‐term variabilitiesCatheterization and Cardiovascular Diagnosis, 1993
- Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease.Circulation, 1991
- Angioscopic coronary macromorphology in patients with acute coronary disordersThe Lancet, 1991
- Accuracy of angiographic determination of left main coronary arterial narrowing. Angiographic--histologic correlative analysis in 28 patients.Circulation, 1981
- Comparison of angiographic and postmortem findings in patients with coronary artery diseaseThe American Journal of Cardiology, 1975