Tests of EEG localization accuracy using implanted sources in the human brain
- 1 February 1991
- journal article
- research article
- Published by Wiley in Annals of Neurology
- Vol. 29 (2), 132-138
- https://doi.org/10.1002/ana.410290204
Abstract
The accuracy with which electrical sources in the brain can be localized by using electroencephalograms measured on the scalp is not well known. In this study, tests of localization accuracy were performed by using implanted dipolar sources in the human brain. These dipoles are created by passing a weak (subthreshold) current through intracerebral electrodes implanted in the brains of epileptic patients for seizure monitoring. The locations of these dipoles are accurately known from roentgenographs. First, 16 electroencephalograms produced by these dipoles were recorded, then inverse solutions were calculated for the apparent sources of these electroencephalograms. Finally, the locations of the apparent sources were compared with the known locations of the implanted dipoles to determine localization error. The average localization error for a total of 28 dipoles in 3 subjects was 1.1 cm. These results indicate that good localization accuracy for focal sources in the brain can be provided by scalp electroencephalograms.Keywords
This publication has 13 references indexed in Scilit:
- MEG versus EEG localization test using implanted sources in the human brainAnnals of Neurology, 1990
- An improved method for localizing electric brain dipolesIEEE Transactions on Biomedical Engineering, 1990
- Electric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its AccuracyIEEE Transactions on Biomedical Engineering, 1987
- The influence of model parameters on EEG/MEG single dipole source estimationIEEE Transactions on Biomedical Engineering, 1987
- A reliable method for localizing deep intracranial sources of the EEGNeurology, 1985
- A Comparison of Moving Dipole Inverse Solutions Using EEG's and MEG'sIEEE Transactions on Biomedical Engineering, 1985
- Accuracy of Dipole Localization with a Spherical Homogeneous ModelIEEE Transactions on Biomedical Engineering, 1983
- Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp ThicknessesIEEE Transactions on Biomedical Engineering, 1981
- Methods for the Localization of Electrical Sources in the Human BrainPublished by Elsevier ,1980
- Evaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human BrainIEEE Transactions on Biomedical Engineering, 1978