A laser Doppler instrument for in vivo measurements of blood flow in single renal arterioles
- 1 March 1993
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 40 (3), 290-297
- https://doi.org/10.1109/10.216413
Abstract
A laser Doppler instrument has been developed to measure the blood flow in single vessels for the study of the dynamics of local control mechanisms. A commercial blood perfusion monitor, designed to measure blood perfusion in a vascular field containing many randomly oriented blood vessels, was modified to perform measurements of blood flow in a single arteriole. In vitro tests of the instrument revealed that the relationship between blood flow and Doppler shift was not a simple linear function. Causes of nonlinearity are revealed and proper use of the device avoids the problem. The device was applied to efferent arterioles that are visible on the surface of the rat kidney. An angiotensin converting enzyme inhibitor and graded doses of angiotensin II were used to perturb kidney blood flow. The induced changes in whole kidney blood flow, measured with an electromagnetic flow probe, and in single efferent arteriolar blood flow, measured with the new instrument, were correlated. An oscillation at approximately 0.035 Hz, previously described in the tubular pressure and attributed to a local feedback mechanism acting on arteriolar resistance, was found in the arteriolar blood flow. The new instrument is easy to use and provides temporal resolution not available with more conventional methods used for flow measurement in the microcirculation.Keywords
This publication has 9 references indexed in Scilit:
- In vivocomparison of a twin wavelength laser Doppler flowmeter using He—Ne and laser diode sourcesJournal of Medical Engineering & Technology, 1990
- Laser-Doppler Blood FlowmetryPublished by Springer Nature ,1990
- Synchronization of proximal intratubular pressure oscillations: evidence for interaction between nephronsPflügers Archiv - European Journal of Physiology, 1987
- Penetration of unfocused laser light into the skinArchives of Dermatological Research, 1985
- Feedback control of glomerular blood flow, pressure, and filtration ratePhysiological Reviews, 1979
- Method for simultaneous determination of red cell and plasma flow velocityin vitro andin vivoPflügers Archiv - European Journal of Physiology, 1976
- Erythrocyte velocity measurement in microvessels by a two-slit photometric method.Journal of Applied Physiology, 1967