Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE)
Open Access
- 27 March 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 57 (4), 731-741
- https://doi.org/10.1002/mrm.21187
Abstract
Echo-planar imaging (EPI) is vulnerable to geometric distortion and N/2 ghosting. These artifacts can be analyzed with an intuitive k-t space tool, and here we propose a simple method for their correction. In a slightly modified additional EPI acquisition, we sample the k-t space with a shift in ky by adding a small area to the phase-encoding (PE) gradient. Physically, the added gradient area creates a relative phase ramp across the object and directly encodes the undistorted original y-coordinate of each voxel into a phase difference between two distorted complex images, in a method called “phase labeling for additional coordinate encoding” (PLACE). The phase information is then used to map the mismapped signals back to their original locations for geometric and intensity correction. Smoothing of expanded complex data matrix effectively reduces noise in the differential phase map and allows subpixel warping. The two acquired images can also be averaged to effectively suppress the N/2 ghost. Efficient correction for both artifacts can be achieved with three acquisitions. These acquisitions can also serve as reference scans to correct for geometric distortion and/or N/2 ghost artifacts on all images in a time series. The technique was successfully demonstrated in phantom and animal studies. Magn Reson Med 57:731–741, 2007.Keywords
This publication has 29 references indexed in Scilit:
- Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPINeuroImage, 2006
- Accelerating MRI by skipped phase encoding and edge deghosting (SPEED)Magnetic Resonance in Medicine, 2005
- Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRINeuroImage, 2005
- New approach for correcting distortions in echo planar imagingMagnetic Resonance in Medicine, 2004
- Removal of EPI Nyquist ghost artifacts with two‐dimensional phase correctionMagnetic Resonance in Medicine, 2004
- A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulationIEEE Transactions on Medical Imaging, 2003
- K‐space description for MR imaging of dynamic objectsMagnetic Resonance in Medicine, 1993
- Numerical TransformsScience, 1990
- Real‐time movie imaging from a single cardiac cycle by NMRMagnetic Resonance in Medicine, 1987
- A simple graphical representation of fourier-based imaging methodsJournal of Magnetic Resonance (1969), 1983