Hand-held blood gas analyzer is accurate in the critical care setting
- 1 June 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 24 (6), 957-962
- https://doi.org/10.1097/00003246-199606000-00014
Abstract
To determine the accuracy of a new, portable battery-powered blood gas analyzer when used by nonlaboratory-trained clinicians in the critical care setting. Prospective analysis of blood samples from critically ill patients. Large tertiary critical care unit. Heterogeneous group of medical and surgical critically ill patients. None. Two hundred thirty-nine split blood samples from intensive care patients were analyzed by clinicians in the critical care environment using a new, portable, battery-powered blood gas analyzer (Immediate Response Mobile Analyzer [IRMA], Diametrics Medical, St. Paul, MN). Near-patient measurements were compared with measurements obtained by laboratory technologists using an IL-1312 blood gas analyzer (Instrumentation Laboratories, Lexington, MA) in an established near-patient critical care laboratory. Precision and coefficients of variation were also determined using repeated testing of quality control samples at three levels of pH, PO2, and PCO2. There was good agreement between IRMA determinations and the laboratory. Correlation coefficients ranged from 0.96 to 0.99. Bias and precision (+/-2 SD), respectively, were 0.02 and 0.036 units for pH, -0.3 torr (1.8 kPa) (-0.04 kPa) and 7.2 torr (0.96 kPa) for PCO2 and -3.9 torr (0.52 kPa) and 13.8 torr (1.8 kPa) for PO2. Precision on repeated testing of quality control samples ranged from 0.022 to 0.04 units for a pH of 7.2 to 7.6, 1.2 to 4.6 torr (0.16 to 0.61 kPa) for a PCO2 of 20 to 60 torr (2.7 to 8 kPa), and 3.0 to 7.4 torr (0.40 to 0.99 kPa) for a PO2 of 70 to 160 torr (9.3 to 21.3 kPa). Coefficients of variation ranged from 0.15% to 0.28% for a pH of 7.2 to 7.6, 2.0% to 3.7% for a PCO2 of 20 to 60 torr (2.7 to 8.0 kPa), and 1.7% to 3.6% for a PO2 of 70 to 160 torr (9.3 to 21.3 kPa). Mean turnaround time was 16.5 +/-10.1 mins for the near-patient laboratory and 2+/-0.5 mins for IRMA. IRMA is accurate and reproducible when used in the clinical setting by nonlaboratory-trained individuals. Nonlaboratory-trained individuals can obtain laboratory results in the critical care setting comparable with the results obtained by trained laboratory technologists. Bedside laboratory testing decreases turnaround time compared with a near-patient laboratory.Keywords
This publication has 10 references indexed in Scilit:
- Sedation for mechanically ventilated patientsCritical Care Medicine, 1994
- Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failureCritical Care Medicine, 1994
- Performance Characteristics and Interanalyzer Variability of PO2Measurements Using Tonometered Human BloodAmerican Review of Respiratory Disease, 1993
- Initial evaluation of a new intra-arterial blood gas system in humansCritical Care Medicine, 1993
- Clinical performance of a blood gas monitorCritical Care Medicine, 1993
- A clinical evaluation of a blood conservation device in medical intensive care unit patientsCritical Care Medicine, 1993
- Blood conservation in critical care—The evidence accumulatesCritical Care Medicine, 1993
- Bedside Diagnostic Blood TestingPublished by American Medical Association (AMA) ,1991
- Bedside blood gas and electrolyte monitoring in critically ill patientsCritical Care Medicine, 1989
- Statistics and ethics in medical research. VI--Presentation of results.BMJ, 1980