Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT
Top Cited Papers
- 1 August 2012
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 264 (2), 567-580
- https://doi.org/10.1148/radiol.12112265
Abstract
This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clinical practice, industry, and regulatory and funding agencies to identify the steps required to reduce the effective dose from routine CT examinations to less than 1 mSv. The most promising technologies and methods discussed at the summit include innovations and developments in x-ray sources; detectors; and image reconstruction, noise reduction, and postprocessing algorithms. Access to raw projection data and standard data sets for algorithm validation and optimization is a clear need, as is the need for new, clinically relevant metrics of image quality and diagnostic performance. Current commercially available techniques such as automatic exposure control, optimization of tube potential, beam-shaping filters, and dynamic z-axis collimators are important, and education to successfully implement these methods routinely is critically needed. Other methods that are just becoming widely available, such as iterative reconstruction, noise reduction, and postprocessing algorithms, will also have an important role. Together, these existing techniques can reduce dose by a factor of two to four. Technical advances that show considerable promise for additional dose reduction but are several years or more from commercial availability include compressed sensing, volume of interest and interior tomography techniques, and photon-counting detectors. This report offers a strategic roadmap for the CT user and research and manufacturer communities toward routinely achieving effective doses of less than 1 mSv, which is well below the average annual dose from naturally occurring sources of radiation. © RSNA, 2012Keywords
This publication has 91 references indexed in Scilit:
- Correlation between model observer and human observer performance in CT imaging when lesion location is uncertainMedical Physics, 2013
- Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic AngiographyJournal of Computer Assisted Tomography, 2011
- Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experienceThe International Journal of Cardiovascular Imaging, 2010
- The Medical Image Perception Society Update on Key Issues for Image Perception ResearchRadiology, 2009
- Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithmsPhysics in Medicine & Biology, 2009
- Compressed sensing based interior tomographyPhysics in Medicine & Biology, 2009
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- Image covariance and lesion detectability in direct fan-beam x-ray computed tomographyPhysics in Medicine & Biology, 2008
- Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quantaPhysics in Medicine & Biology, 2007
- Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomographyIEEE Transactions on Medical Imaging, 2000