Feasibility and development of a high-power real accommodating intraocular lens
- 1 September 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (9), 1802-1808
- https://doi.org/10.1016/j.jcrs.2005.06.037
Abstract
To develop an accommodating intraocular lens (IOL) that changes power with ciliary body action and generates a minimum of 8.0 diopters (D) by manipulation of a flexible material between a sulcus-fixated rigid plate and a ciliary muscle-operated capsular diaphragm. Vissum-Instituto Oftalmológico de Alicante and Miguel Hernández University, Alicante, Spain. The feasibility of the concept was tested by a laboratory lens model. An implantable measuring device was constructed to simulate the lens action. The device was implanted in monkey eyes to measure the various parameters involved with such IOLs. Based on these measurements, an accommodating IOL prototype was built and implanted in monkeys' eyes. Pharmacologic agents were used to achieve ciliary relaxation and spasm. Ultrasound biomicroscopy (UBM) imaging was used to document the active changes of the IOL flexible lens curvature as related to the ciliary muscles status. The laboratory model produced more than 50.0 D of accommodation. The UBM demonstrated changes in lens curvature between cyclospasm to cycloplegia of calculated 9.0 to 53.0 D for flexible material with a refractive index of 1.41. Flexible material is capable of being manipulated when placed between a scleral-fixated rigid plane and the ciliary muscles-operated capsular diaphragm. Such manipulation as used by the IOL concept presented here has generated an active change of more than 40.0 D in the monkey eye.Keywords
This publication has 12 references indexed in Scilit:
- Relationship between anterior capsule contraction and posterior capsule opacification after cataract surgery in patients with diabetes mellitusJournal of Cataract & Refractive Surgery, 2004
- Functional and structural analysis of the visual system in the rhesus monkey model of optic nerve head ischemia.Investigative Opthalmology & Visual Science, 2004
- Comparison of 6-month results of implantation of the 1CU accommodative intraocular lens with conventional intraocular lensesOphthalmology, 2004
- Subjective and objective measurement of human accommodative amplitudeJournal of Cataract & Refractive Surgery, 2003
- Intraocular lens movement caused by ciliary muscle contractionJournal of Cataract & Refractive Surgery, 2003
- Intraocular lens movement and accommodation in eyes of young patientsJournal of Cataract & Refractive Surgery, 2000
- AMO array multifocal lens versus monofocal correction in cataract surgeryJournal of Cataract & Refractive Surgery, 2000
- Effect of intraocular lens and anterior capsule opening type on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1999
- Temporal dynamics of chromatic tuning in macaque primary visual cortexNature, 1998
- Amplitude of Accommodation for Different Head Positions and Different Directions of Eye GazeOptometry and Vision Science, 1994