Towards adaptive IMRT sequencing for the MR-linac
- 6 March 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (6), 2493-2509
- https://doi.org/10.1088/0031-9155/60/6/2493
Abstract
The MRI linear accelerator (MR-linac) that is currently being installed in the University Medical Center Utrecht (Utrecht, The Netherlands), will be able to track the patient's target(s) and Organ(s) At Risk during radiation delivery. In this paper, we present a treatment planning system for intensity-modulated radiotherapy (IMRT). It is capable of Adaptive Radiotherapy and consists of a GPU Monte Carlo dose engine, an inverse dose optimization algorithm and a novel adaptive sequencing algorithm. The system is able to compensate for patient anatomy changes and enables radiation delivery immediately from the first calculated segment. IMRT plans meeting all clinical constraints were generated for two breast cases, one spinal bone metastasis case, two prostate cases with integrated boost regions and one head and neck case. These plans were generated by the segment weighted version of our algorithm, in a 0 T environment in order to test the feasibility of the new sequencing strategy in current clinical conditions, yielding very small differences between the fluence and sequenced distributions. All plans went through stringent experimental quality assurance on Delta4 and passed all clinical tests currently performed in our institute. A new inter-fraction adaptation scheme built on top of this algorithm is also proposed that enables convergence to the ideal dose distribution without the need of a final segment weight optimization. The first results of this method confirm that convergence is achieved within the first fractions of the treatment. These features combined will lead to a fully adaptive intra-fraction planning system able to take into account patient anatomy updates during treatment.Keywords
This publication has 28 references indexed in Scilit:
- Fast dose calculation in magnetic fields withGPUMCDPhysics in Medicine & Biology, 2011
- Monte Carlo characterization of skin doses in 6 MV transverse field MRI‐linac systems: Effect of field size, surface orientation, magnetic field strength, and exit bolusMedical Physics, 2010
- Magnetic field effects on the energy deposition spectra of MV photon radiationPhysics in Medicine & Biology, 2008
- Dose optimization for the MRI-accelerator: IMRT in the presence of a magnetic fieldPhysics in Medicine & Biology, 2007
- Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculationsMedical Physics, 2007
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic fieldPhysics in Medicine & Biology, 2007
- Decomposition of integer matrices and multileaf collimator sequencingDiscrete Applied Mathematics, 2005
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electronsPhysics in Medicine & Biology, 2005
- Direct aperture optimization: A turnkey solution for step‐and‐shoot IMRTMedical Physics, 2002
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994