Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis
- 1 December 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (2), 493-500
- https://doi.org/10.1021/ac0514624
Abstract
Proteomic analysis of digested complex protein mixtures has become a useful strategy to identify proteins involved in biological processes. We have evaluated the use of a new mass spectrometer that combines a linear ion trap and an Orbitrap to create a hybrid tandem mass spectrometer. A digested submandibular/sublingual saliva sample was used for the analysis. We find the instrument is capable of mass resolution in excess of 40 000 and mass measurement accuracies of less than 2 ppm for the analysis of complex peptide mixtures. Such high mass accuracy allowed the elimination of virtually any false positive peptide identifications, suggesting that peptides that do not match the specificity of the protease used in the digestion of the sample should not automatically be considered as false positives. Tandem mass spectra from the linear ion trap and from the Orbitrap have very similar ion abundance ratios. We conclude this instrument will be well suited for shotgun proteomic types of analyses.Keywords
This publication has 21 references indexed in Scilit:
- The mammalian Mediator complexFEBS Letters, 2004
- Automatic Quality Assessment of Peptide Tandem Mass SpectraBioinformatics, 2004
- Human and mouse proteases: a comparative genomic approachNature Reviews Genetics, 2003
- Evaluation of Multidimensional Chromatography Coupled with Tandem Mass Spectrometry (LC/LC−MS/MS) for Large-Scale Protein Analysis: The Yeast ProteomeJournal of Proteome Research, 2002
- Empirical Statistical Model To Estimate the Accuracy of Peptide Identifications Made by MS/MS and Database SearchAnalytical Chemistry, 2002
- A two-dimensional quadrupole ion trap mass spectrometerJournal of the American Society for Mass Spectrometry, 2002
- Efficient sequence analysis of the six gene products (7‐74 kDA) from the escherichia coli thiamin biosynthetic operon by tandem high‐resolution mass spectrometryProtein Science, 1998
- Submandibular Salivary Proteases: Lack of a Role in Anti-HIV ActivityJournal of Dental Research, 1998
- Direct Analysis and Identification of Proteins in Mixtures by LC/MS/MS and Database Searching at the Low-Femtomole LevelAnalytical Chemistry, 1997
- Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule SequencingAnalytical Chemistry, 1994