Electrical Storm Presages Nonsudden Death
Top Cited Papers
- 24 April 2001
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 103 (16), 2066-2071
- https://doi.org/10.1161/01.cir.103.16.2066
Abstract
Background—Electrical storm, multiple temporally related episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF), is a frequent problem among recipients of implantable cardioverter defibrillators (ICDs). However, insufficient data exist regarding its prognostic significance. Methods and Results—This analysis includes 457 patients who received an ICD in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial and who were followed for 31±13 months. Electrical storm was defined as ≥3 separate episodes of VT/VF within 24 hours. Characteristics and survival of patients surviving electrical storm (n=90), those with VT/VF unrelated to electrical storm (n=184), and the remaining patients (n=183) were compared. The 3 groups differed in terms of ejection fraction, index arrhythmia, revascularization status, and baseline medication use. Survival was evaluated using time-dependent Cox modeling. Electrical storm occurred 9.2±11.5 months after ICD implantation, and most episodes (86%) were due to VT. Electrical storm was a significant risk factor for subsequent death, independent of ejection fraction and other prognostic variables (relative risk [RR], 2.4; 95% confidence interval [CI], 1.3 to 4.2; P=0.003), but VT/VF unrelated to electrical storm was not (RR, 1.0; 95% CI, 0.6 to 1.7; P=0.9). The risk of death was greatest 3 months after electrical storm (RR, 5.4; 95% CI, 2.4 to 12.3; P=0.0001) and diminished beyond this time (RR, 1.9; 95% CI, 1.0 to 3.6; P=0.04). Conclusions—Electrical storm is an important, independent marker for subsequent death among ICD recipients, particularly in the first 3 months after its occurrence. However, the development of VT/VF unrelated to electrical storm does not seem to be associated with an increased risk of subsequent death.Keywords
This publication has 22 references indexed in Scilit:
- A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1999
- Causes of death in the antiarrhythmics versus implantable defibrillators (AVID) trialJournal of the American College of Cardiology, 1999
- The Effect of Spironolactone on Morbidity and Mortality in Patients with Severe Heart FailureNew England Journal of Medicine, 1999
- TIME-DEPENDENT COVARIATES IN THE COX PROPORTIONAL-HAZARDS REGRESSION MODELAnnual Review of Public Health, 1999
- The Cardiac Insufficiency Bisoprolol Study II (CIBIS-II): a randomised trialThe Lancet, 1999
- Ventricular Fibrillation-induced Intracellular Ca2+Overload Causes Failed Electrical Defibrillation and Post-shock Reinitiation of FibrillationJournal of Molecular and Cellular Cardiology, 1998
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaNew England Journal of Medicine, 1996
- Antiarrhythmics Versus Implantable Defibrillators (AVID)—Rationale, design, and methodsThe American Journal of Cardiology, 1995
- Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillatorJournal of the American College of Cardiology, 1994
- Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter-defibrillatorJournal of the American College of Cardiology, 1987