Dose Reduction in Abdominal Computed Tomography
Top Cited Papers
- 1 July 2011
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 46 (7), 465-470
- https://doi.org/10.1097/rli.0b013e31821690a1
Abstract
We sought to evaluate the image quality of iterative reconstruction in image space (IRIS) in half-dose (HD) datasets compared with full-dose (FD) and HD filtered back projection (FBP) reconstruction in abdominal computed tomography (CT). To acquire data with FD and HD simultaneously, contrast-enhanced abdominal CT was performed with a dual-source CT system, both tubes operating at 120 kV, 100 ref.mAs, and pitch 0.8. Three different image datasets were reconstructed from the raw data: Standard FD images applying FBP which served as reference, HD images applying FBP and HD images applying IRIS. For the HD data sets, only data from 1 tube detector-system was used. Quantitative image quality analysis was performed by measuring image noise in tissue and air. Qualitative image quality was evaluated according to the European Guidelines on Quality criteria for CT. Additional assessment of artifacts, lesion conspicuity, and edge sharpness was performed. : Image noise in soft tissue was substantially decreased in HD-IRIS (-3.4 HU, -22%) and increased in HD-FBP (+6.2 HU, +39%) images when compared with the reference (mean noise, 15.9 HU). No significant differences between the FD-FBP and HD-IRIS images were found for the visually sharp anatomic reproduction, overall diagnostic acceptability (P = 0.923), lesion conspicuity (P = 0.592), and edge sharpness (P = 0.589), while HD-FBP was rated inferior. Streak artifacts and beam hardening was significantly more prominent in HD-FBP while HD-IRIS images exhibited a slightly different noise pattern. Direct intrapatient comparison of standard FD body protocols and HD-IRIS reconstruction suggest that the latest iterative reconstruction algorithms allow for approximately 50% dose reduction without deterioration of the high image quality necessary for confident diagnosis.Keywords
This publication has 30 references indexed in Scilit:
- High-Pitch Spiral Computed TomographyInvestigative Radiology, 2011
- Low Dose High-Pitch Spiral Acquisition 128-Slice Dual-Source Computed Tomography for the Evaluation of Coronary Artery Bypass Graft PatencyInvestigative Radiology, 2010
- Dual Energy CT of the ChestInvestigative Radiology, 2010
- Saving Dose in Triple-Rule-Out Computed Tomography Examination Using a High-Pitch Dual Spiral TechniqueInvestigative Radiology, 2010
- Dose Reduction for Semi-Automated Volumetry of Hepatic Metastasis in MDCT StudiesInvestigative Radiology, 2010
- Reduction of Radiation Dose Estimates in Cardiac 64-Slice CT Angiography in Patients After Coronary Artery Bypass Graft SurgeryInvestigative Radiology, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: Estimates of Radiation-Related Cancer RisksRadiation Research, 2007
- Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi–Detector Row CT Examinations: Clinical EvaluationRadiology, 2005
- Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regionsEuropean Radiology, 2000