Abstract
The Rogowski coil is a well-known current-to-voltage transducer. To use it for the high-accuracy measurement of AC current (at power supply frequency), all influencing quantities and their contribution should be recognized and analyzed. Thus, the partial influence due to the deviation from the central position of the primary conductor for a real sensor, with the nonhomogeneous density of secondary turns, is given in this paper. The measured deviation of mutual inductance in this case showed very good agreement with the theoretical prediction, which is promising for the expected application of such a sensor.Keywords
This publication has 5 references indexed in Scilit:
- Mutual Inductance of a Precise Rogowski Coil in Dependence of the Position of Primary ConductorIEEE Transactions on Instrumentation and Measurement, 2008
- Analysis of the mutual inductance of a precise Rogowski coilPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2007
- Design and Characteristics of Two Rogowski Coils Based on Printed Circuit BoardIEEE Transactions on Instrumentation and Measurement, 2006
- High performance Rogowski current transducersPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Machinable Rogowski coil, design, and calibrationIEEE Transactions on Instrumentation and Measurement, 1996