Endoneural selective stimulating using wire-microelectrode arrays
- 1 December 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Rehabilitation Engineering
- Vol. 7 (4), 399-412
- https://doi.org/10.1109/86.808943
Abstract
In acute experiments eight 5- to 24-wire-microelectrode arrays were inserted into the common peroneal nerve of the rat, to investigate whether the electrodes could selectively stimulate motor units of the extensor digitorum longus (EDL) muscle. Twitch-force-recruitment curves were measured from the EDL for each array electrode. The curves were plotted on a double-logarithmic scale and parameterized by the low-force slope (which represents the power p in the power-law relationship of force F versus stimulus current I, or F/spl sim/I/sup p/) and the threshold current. The slopes and threshold currents measured with array electrodes did not differ significantly from those obtained with randomly inserted single wire-microelectrodes. This indicates that, although involving a more invasive insertion procedure, electrode arrays provide neural contacts with low-force recruitment properties similar to those of single wires. Array results revealed partial blocking of neural conduction, similar to that reported with microneurographic insertion with single needles. The efficiency of the array was defined as the fraction of array electrodes selectively contacting a motor unit and evoking the corresponding threshold force. Efficiency thus expresses the practical value of the used electrode array in terms of the total number of distinct threshold forces that can be stimulated by selecting the appropriate electrodes. The eight arrays were capable of evoking threshold forces selectively with an average efficiency of 0.81 (or 81%).Keywords
This publication has 24 references indexed in Scilit:
- The effect of stimulus pulse duration on selectivity of neural stimulationIEEE Transactions on Biomedical Engineering, 1996
- Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulationIEEE Transactions on Biomedical Engineering, 1996
- 3D neuro-electronic interface devices for neuromuscular control: Design studies and realisation stepsBiosensors and Bioelectronics, 1995
- Selective control of muscle activation with a multipolar nerve cuff electrodeIEEE Transactions on Biomedical Engineering, 1993
- Muscle recruitment with intrafascicular electrodesIEEE Transactions on Biomedical Engineering, 1991
- Selective activation of small motor axons by quasitrapezoidal current pulsesIEEE Transactions on Biomedical Engineering, 1991
- A method to effect physiological recruitment order in electrically activated muscleIEEE Transactions on Biomedical Engineering, 1991
- Orderly stimulation of skeletal muscle motor units with tripolar nerve cuff electrodeIEEE Transactions on Biomedical Engineering, 1989
- Microneurography for the recording and selective stimulation of afferents: An assessmentMuscle & Nerve, 1988
- Motor, sympathetic and sensory innervation of rat skeletal musclesBrain Research, 1986