In vivo analysis of biocompatibility and vascularization of the synthetic bone grafting substitute NanoBone®
- 4 November 2008
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 91A (2), 557-566
- https://doi.org/10.1002/jbm.a.32237
Abstract
One of the major challenges in the application of bone substitutes is adequate vascularization and biocompatibility of the implant. Thus, the temporal course of neovascularization and the microvascular inflammatory response of implants of NanoBone® (fully synthetic nanocrystalline bone grafting material) were studied in vivo by using the mouse dorsal skinfold chamber model. Angiogenesis, microhemodynamics, and leukocyte‐endothelial cell interaction were analyzed repetitively after implantation in the center and in the border zone of the implant up to 15 days. Both NanoBone® granules and plates exhibited high biocompatibility comparable to that of cancellous bone, as indicated by a lack of venular leukocyte activation after implantation. In both synthetic NanoBone® groups, signs of angiogenesis could be observed even at day 5 after implantation, whereas granules showed higher functional vessel density compared with NanoBone® plates. The angiogenic response of the cancellous bone was markedly accelerated in the center of the implant tissue. Histologically, implant tissue showed an ingrowth of vascularized fibrous tissue into the material combined with an increased number of foreign‐body giant cells. In conclusion, NanoBone®, particularly in granular form, showed high biocompatibility and high angiogenic response, thus improving the healing of bone defects. Our results underline that, beside the composition and nanostructure, the macrostructure is also of importance for the incorporation of the biomaterial by the host tissue. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res 2009Keywords
This publication has 21 references indexed in Scilit:
- Injectable nanocrystalline hydroxyapatite paste for bone substitution: In vivo analysis of biocompatibility and vascularizationJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Angiogenesis in Tissue Engineering: Breathing Life into Constructed Tissue SubstitutesTissue Engineering, 2006
- Buried alive: How osteoblasts become osteocytesDevelopmental Dynamics, 2005
- Histological assessment in grafts of highly purified beta-tricalcium phosphate (OSferion®) in human bonesBiomaterials, 2005
- Wear particles and surface topographies are modulators of osteoclastogenesis in vitroJournal of Biomedical Materials Research Part A, 2004
- Viewing the Microcirculation through the Window: Some Twenty Years Experience with the Hamster Dorsal Skinfold ChamberEuropean Surgical Research, 2002
- Synthetic bone graft substitutesAnz Journal of Surgery, 2001
- Cap Image - ein neuartiges computerunterstütztes Videobildanalysesystem für die dynamische Kapillarmikroskopie - Cap Image - A Newly-developed Computer-aided Videoframe Analysis System for Dynamic CapillaroscopyBiomedizinische Technik/Biomedical Engineering, 1997
- Technical report—a new chamber technique for microvascular studies in unanesthetized hamstersZeitschrift für Die Gesamte Experimentelle Medizin, 1980
- On-line volume flow rate and velocity profile measurement for blood in microvesselsMicrovascular Research, 1974