Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays
- 30 June 2009
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (14), 4605-4619
- https://doi.org/10.1088/0031-9155/54/14/015
Abstract
Small animal PET scanners may be improved by increasing the sensitivity, improving the spatial resolution and improving the uniformity of the spatial resolution across the field of view. This may be achieved by using PET detectors based on crystal elements that are thin in the axial and transaxial directions and long in the radial direction, and by employing depth of interaction (DOI) encoding to minimize the parallax error. With DOI detectors, the diameter of the ring of the PET scanner may also be decreased. This minimizes the number of detectors required to achieve the same solid angle coverage as a scanner with a larger ring diameter and minimizes errors due to non-collinearity of the annihilation photons. In this study, we characterize prototype PET detectors that are finely pixelated with individual LSO crystal element sizes of 0.5 mm x 0.5 mm x 20 mm and 0.7 mm x 0.7 mm x 20 mm, read out at both ends by position sensitive avalanche photodiodes (PSAPDs). Both a specular reflector and a diffuse reflector were evaluated. The detectors were characterized based on the ability to clearly resolve the individual crystal elements, the DOI resolution and the energy resolution. Our results indicate that a scanner based on any of the four detector designs would offer improved spatial resolution and more uniform spatial resolution compared to present day small animal PET scanners. The greatest improvements to spatial resolution will be achieved when the detectors employing the 0.5 mm x 0.5 mm x 20 mm crystals are used. Monte Carlo simulations were performed to demonstrate that 2 mm DOI resolution is adequate to ensure uniform spatial resolution for a small animal PET scanner geometry using these detectors. The sensitivity of such a scanner was also simulated using Monte Carlo simulations and was shown to be greater than 10% for a four ring scanner with an inner diameter of 6 cm, employing 20 detectors per scanner ring.Keywords
This publication has 24 references indexed in Scilit:
- Monolithic scintillator PET detectors with intrinsic depth-of-interaction correctionPhysics in Medicine & Biology, 2009
- A Prototype PET Scanner with DOI-Encoding DetectorsJournal of Nuclear Medicine, 2008
- Partial-Volume Effect in PET Tumor ImagingJournal of Nuclear Medicine, 2007
- Monte Carlo simulations of absorbed dose in a mouse phantom from 18‐fluorine compoundsMedical Physics, 2007
- Measurement of input functions in rodents: challenges and solutionsNuclear Medicine and Biology, 2005
- Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectorsIEEE Transactions on Nuclear Science, 2002
- Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodesIEEE Transactions on Nuclear Science, 1999
- Initial results from the Sherbrooke avalanche photodiode positron tomographIEEE Transactions on Nuclear Science, 1996
- A room temperature LSO/PIN photodiode PET detector module that measures depth of interactionIEEE Transactions on Nuclear Science, 1995
- The design and physical characteristics of a small animal positron emission tomographPhysics in Medicine & Biology, 1995