Abstract
To evaluate flap dimensions and cut deterioration with repeated blade use in an automated microkeratome. The Automated Corneal Shaper (Chiron-Adatomed, Munich, Germany), 160-microm plate attached, was used to make a corneal flap in 90 pig cadaver eyes, reusing blades up to five times. Flap diameter was measured by planimetry and thickness was calculated by ultrasound pachymetry. Scanning electron microscopy of stromal beds and blade cutting edges was performed to assess cut deterioration after repeated blade use. Mean flap central thickness was 125 +/- 32 microm. Mean vertical flap diameter was 7.6 +/- 0.4 mm. No correlation was found between thickness and diameter (r = 0.15, P = .45). Progressive thinning of the flap was observed in the direction of the flap hinge. Smooth cuts (using new blades) with periodic chatter lines at the keratectomy edge and in the stromal bed were observed with scanning electron microscopy. Increasing tissue remnants on the stromal bed and decreasing cut quality occurred with repeated blade use. Blades showed larger tissue remnants, nicks, and even folds on the cutting edge proportional to the number of times blades were used. Satisfactory cut quality and reproducibility were obtained after a single use of stainless steel blades in the Automated Corneal Shaper microkeratome. Cut quality was degraded dramatically by repeated use of blades.Keywords
This publication has 25 references indexed in Scilit:
- LASIKCornea, 1998
- Diffuse lamellar keratitis A new syndrome in lamellar refractive surgeryOphthalmology, 1998
- Photorefractive keratectomy versus laser in situ keratomileusis for moderate to high myopia: A randomized prospective studyOphthalmology, 1998
- Laser in situ keratomileusis (LASIK) in myopia: 2-year resultsDer Ophthalmologe, 1998
- Laser in situ keratomileusis for moderate and high myopia and myopic astigmatismOphthalmology, 1998
- Outcome of Cornea, Iris, and Lens Perforation During Automated Lamellar KeratectomyArchives of Ophthalmology (1950), 1996
- Experience during the learning curve of laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1996
- Complications of Automated Lamellar KeratectomyArchives of Ophthalmology (1950), 1994
- Lamellar excimer laser keratoplasty: Reproducible photoablation of corneal tissueDocumenta Ophthalmologica, 1992
- Laser in situ keratomileusisLasers in Surgery and Medicine, 1990