Comparison of narrow-band reflectance spectroscopy and tristimulus colorimetry for measurements of skin and hair color in persons of different biological ancestry
- 1 May 2000
- journal article
- Published by Wiley in American Journal of Physical Anthropology
Abstract
We have used two modern computerized handheld reflectometers, the Photovolt ColorWalk colorimeter (a tristimulus colorimeter; Photovolt, UMM Electronics, Indianapolis, IN) and the DermaSpectrometer (a specialized narrow‐band reflectometer; Cortex Technology, Hadsund, Denmark), to compare two methods for the objective determination of skin and hair color. These instruments both determine color by measuring the intensity of reflected light of particular wavelengths. The Photovolt ColorWalk instrument does so by shining a white light and sensing the intensity of the reflected light with a linear photodiode array. The ColorWalk results can then be expressed in terms of several standard color systems, most importantly, the Commission International d'Eclairage (CIE) Lab system, in which any color can be described by three values: L*, the lightness; a*, the amount of green or red; and b*, the amount of yellow or blue. Instead of a white light and photodiodes, the DermaSpectrometer uses two light‐emitting diodes (LEDs), one green and one red, to illuminate a surface, and then it records the intensity of the reflected light. The results of these readings are expressed in terms of erythema (E) and melanin (M) indices. We measured the unexposed skin of the inner upper arm, the exposed skin of the forehead, and the hair, of 80 persons using these two instruments. Since it is important for the application of these measures in anthropology that we understand their relationship across a number of different pigmentation levels, we sampled persons from several different groups, namely, European Americans (n = 55), African Americans (n = 9), South Asians (n = 7), and East Asians (n = 9). In these subjects, there is a very high correlation between L* and the M index for the inner arm (R2 = 0.928, P < 0.001), the forehead (R2 = 0.822, P < 0.001), and the hair (R2 = 0.827, P < 0.001). The relationship between a* and the E index is complex and dependent on the pigmentation level. We conclude that while both types of instruments provide accurate estimates of pigment level in skin and hair, measurements using narrow‐band instruments may be less affected by the greater redness of certain body sites due to increased vascularization. Am J Phys Anthropol 112:17–27, 2000.Keywords
This publication has 16 references indexed in Scilit:
- Guidelines for measurement skin colour and erythema A report from the Standardization Group of the European Society of Contact Dermatitis*Contact Dermatitis, 1996
- Comparison of Narrow-Band Reflectance Spectrophotometric and Tristimulus Colorimetric Measurements of Skin ColorSkin Pharmacology and Physiology, 1994
- Skin Color Measurements in Terms of CIELAB Color Space ValuesJournal of Investigative Dermatology, 1992
- The Relation Between Constitutional Skin Color and Photosensitivity Estimated from UV-Induced Erythema and Pigmentation Dose-Response CurvesJournal of Investigative Dermatology, 1990
- Absorption Mechanisms of Human Melanin in the Visible, 400–720nmJournal of Investigative Dermatology, 1987
- Spectroscopic Characteristics of Human Melanin In VivoJournal of Investigative Dermatology, 1985
- A portable instrument for quantifying erythema induced by ultraviolet radiationBritish Journal of Dermatology, 1984
- Social class, admixture, and skin color variation in Mexican‐Americans and Anglo‐Americans living in San Antonio, TexasAmerican Journal of Physical Anthropology, 1983
- Skin and hair reflectance in women with red hairAnnals of Human Biology, 1981
- Skin colorimetry and admixture measurement: Some further considerationsAmerican Journal of Physical Anthropology, 1980