Abstract
Theoretical expressions are presented for LK electron capture ratios and electron capture-positron emission ratios that include the effects of electron exchange and imperfect atomic overlap. The role of electron exchange and imperfect atomic overlap in the determination of fluorescence yields is also discussed. In order to facilitate experimental comparisons, numerical values are presented for the exchange and overlap corrections to LK ratios and electrons capture-positron emission ratios; these correctiosn were calculated with the analytic Hartree-Fock wave functions of Watson and Freeman. The corrected LK ratios are in good agreement with the precisely measured LK ratios, showing that overlap and exchange corrections explain the systematic disagreement between the predictions of the usual electron capture theory and experiment.