Radiation from “Extra” Images Acquired with Abdominal and/or Pelvic CT: Effect of Automatic Tube Current Modulation
- 1 August 2004
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 232 (2), 409-414
- https://doi.org/10.1148/radiol.2322031151
Abstract
To retrospectively determine the number and usefulness of images acquired beyond the intended anatomic area of interest with abdominal and/or pelvic computed tomography (CT) and to assess the effect of automatic tube current modulation (ATCM) on associated radiation. Superior and inferior levels at routine abdominal and/or pelvic CT were defined as the dome of the diaphragm and the inferior margin of the pubic symphysis, respectively. Records of 106 consecutive examinations (male-to-female ratio, 45:61; age range, 21-86 years) performed from June 1 to June 30, 2003, were reviewed to determine the number of "extra" images. Sixty-two abdominal and/or pelvic CT examinations performed concurrently with chest or thigh CT or for trauma were not included in the 106. Abdominal and/or pelvic CT was performed with either ATCM (n = 44) or manual selection of tube current (n = 62). CT parameters recorded for each extra image included tube current, peak kilovoltage, and gantry rotation time. Mean and median tube current-time products were calculated for extra images. Extra images were analyzed for pathologic findings. Statistical analysis was performed with the Student t test. Extra images were acquired above the dome of the diaphragm in 103 (97%) of 106 examinations and below the pubic symphysis in 100 (94%) of 106. A total of 1,280 extra images were acquired in 106 examinations (mean, 12 images per examination). Nineteen additional findings were observed on extra images. With ATCM, mean tube current-time product was 74.5 and 120.6 mAs for extra images acquired above the diaphragm and below the pubic symphysis, respectively; with manual selection, mean tube current-time products were 167.5 and 168.3 mAs (P <.05). Most extra images acquired at abdominal and/or pelvic CT contributed no additional information. With ATCM, the radiation dose was reduced by a mean of 56% (median, 72%) for extra images above the diaphragm and 29% (median, 36%) for images below the pubic symphysis, compared with dose levels with manual selection.Keywords
This publication has 10 references indexed in Scilit:
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Low-Dose CT of the Abdomen: Evaluation of Image Improvement with Use of Noise Reduction Filters—Pilot StudyRadiology, 2003
- Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot StudyRadiology, 2003
- Clinical Comparison of Standard-Dose and 50% Reduced—Dose Abdominal CT: Effect on Image QualityAmerican Journal of Roentgenology, 2002
- The ALARA concept in pediatric CT intelligent dose reductionPediatric Radiology, 2002
- Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)European Radiology, 2002
- Minimizing Radiation Dose for Pediatric Body Applications of Single-Detector Helical CTAmerican Journal of Roentgenology, 2001
- Radiation doses in computed tomographyBMJ, 2000
- Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regionsEuropean Radiology, 2000
- Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 1999