Determination and repeatability of maximum oxygen uptake and other cardiorespiratory measurements in the exercising horse
- 1 March 1988
- journal article
- research article
- Published by Wiley in Equine Veterinary Journal
- Vol. 20 (2), 94-98
- https://doi.org/10.1111/j.2042-3306.1988.tb01467.x
Abstract
A rapid incremental treadmill exercise test was used to determine the repeatability of the following measurements in exercising horses: maximal oxygen consumption (.ovrhdot.VO2max), maximal heart rate (HRmax), velocity at a heart rate of 200 beats/min (.ovrhdot.V-200), oxygen consumption at a heart rate of 200 beats/min (.ovrhdot.VO2-200), oxygen consumption at HRmax (.ovrhdot.VO2-HRMAX), work rate at a heart rate of 200 beats/min (w-200), work rate at HRmax (W-HRmax) and treadmill velocity at HRmax (V-HRmax). Six Standardbred geldings were exercised on three separate occasions on a treadmill set at an inclination of 6.degree.. The exercise protocol was that each horse was exercised for 2 mins at 3 m/sec, after which the treadmill speed was increased by 1 m/sec every 60 secs, until the horse could no longer maintain its speed. A minimum of 24 h was allowed between repeated tests. No significant differences were found between the three means of any of the eight cardiorespiratory variables with repeated measurement. Variables with high coefficients of variation (> 10 per cent) included V-HRmax, W-HRmax and .ovrhdot.VO2-HRmax. The V-200, W-200 and .ovrhdot.VO2-200 showed less variation. The .ovrhdot.VO2max showed good reproducibility, there being coefficients of variation ranging from 1.4 to 9.0 per cent. The individual horse values for .ovrhdot.VO2max ranged from 104 to 169 ml/kg bodyweight/min. Maximal heart rate was also highly reproducible and the coefficients of variation were less than or equal to 2.7 per cent in all horses. It is concluded that the measurements of .ovrhdot.VO2max has good reproducibility, but other estimates of maximal aerobic capacity are less precise.This publication has 13 references indexed in Scilit:
- Method of investigation of the accuracy of four digitally‐displaying heart rate meters suitable for use in the exercising horseEquine Veterinary Journal, 1986
- Temporal pattern of pulmonary gas exchange during exercise in poniesJournal of Applied Physiology, 1984
- Tests of Maximum Oxygen Intake A Critical ReviewSports Medicine, 1984
- Design of the mammalian respiratory system. II. Measuring maximum aerobic capacityRespiration Physiology, 1981
- Cerebrospinal fluid acid-base balance during muscular exerciseJournal of Applied Physiology, 1978
- CARDIAC MONITORING DURING EXERCISE TESTS IN THE HORSE.Australian Veterinary Journal, 1975
- New Tests to Assess Lung FunctionNew England Journal of Medicine, 1975
- The Heart Rates of Thoroughbred Horses during a RaceEquine Veterinary Journal, 1970
- Interaction of physiological mechanisms during exercise.Journal of Applied Physiology, 1967