Early Experience with an Implantable Cardioverter
- 23 August 1984
- journal article
- research article
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 311 (8), 485-490
- https://doi.org/10.1056/nejm198408233110801
Abstract
We tested the efficacy and safety of a fully programmable cardioverter weighing 95 g, in terminating sustained ventricular tachycardia. The device was implanted transvenously under local anesthesia in seven patients. On command from a programmer or automatically, the cardioverter delivered shocks through a lead inserted to the apex of the right ventricle. It also served as a demand ventricular pacemaker and could perform programmed ventricular stimulation or overdrive pacing. Cardioversion of ventricular tachycardia required less than 0.5 J (mean) and was well tolerated by the patients, who were awake and not sedated. In one patient, a shock terminated ventricular tachycardia with the device in the automatic mode but produced atrial fibrillation with a rapid ventricular response that was intermittently recognized as ventricular tachycardia, triggering additional shocks. One such shock in the ST segment produced ventricular fibrillation that was terminated transthoracically in the emergency room, without residual impairment.This publication has 11 references indexed in Scilit:
- Potential Hazards of Implanted Devices for the Electrical Control of TachyarrhythmiasPacing and Clinical Electrophysiology, 1984
- Implantation Techniques of Antitachycardia DevicesPacing and Clinical Electrophysiology, 1984
- Electrical Therapy of Cardiac ArrhythmiasNew England Journal of Medicine, 1983
- Low energy counterchock using an intravascular catheter in an acute cardiac care settingThe American Journal of Cardiology, 1982
- Additional observations on transvenous cardioversion of recurrent ventricular tachycardiaAmerican Heart Journal, 1982
- Low-energy synchronous cardioversion of ventricular tachycardia using a catheter electrode in a canine model of subacute myocardial infarction.Circulation, 1982
- Clinical transvenous cardioversion of recurrent life-threatening ventricular tachyarrhythmias: Low energy synchronized cardioversion of ventricular tachycardia and termination of ventricular fibrillation in patients using a catheter electrodeAmerican Heart Journal, 1982
- Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human BeingsNew England Journal of Medicine, 1980
- A chronically implanted system for automatic defibrillation in active conscious dogs. Experimental model for treatment of sudden death from ventricular fibrillation.Circulation, 1978
- Feasibility and Effectiveness of Low-Energy Catheter Defibrillation in ManCirculation, 1973