Kinetic determination of propyl gallate in edible and cosmetic oils with sensitized terbium(III) luminescence detection
- 1 January 1995
- journal article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 120 (1), 125-128
- https://doi.org/10.1039/an9952000125
Abstract
A very fast, selective kinetic method for the determination of propyl gallate is proposed. The analytical parameter used for this purpose is the initial rate of the luminescence reaction between propyl gallate and terbium(III) in the presence of sodium dodecyl sulfate, and is calculated from the slope of a kinetic plot of the luminescence signal as a function of time. The luminescence signal arises from an intramolecular energy transfer between excited propyl gallate and terbium(III), which is followed by the lanthanide emission. Kinetic data can be obtained within only 0.2 s, which entails using the stopped-flow mixing technique but facilitates automation. The calibration graph is linear over the range 0.08–3.0 µg ml–1 propyl gallate and the detection limit is 0.02 µg ml–1. The relative standard deviation is close to 2%. The proposed method was applied to the determination of propyl gallate in various edible and cosmetic oil samples with a mean recovery of 99.1%.This publication has 12 references indexed in Scilit:
- Determination of steroids in urine by micellar HPLC with detection by sensitized terbium fluorescenceAnalytical Chemistry, 1993
- Stopped-flow determination of diphacinone based on lanthanide-sensitized luminescenceAnalytica Chimica Acta, 1993
- Lanthanide-sensitized luminescence and applications to the determination of organic analytes. A reviewThe Analyst, 1993
- Determination of plutonium-239 + plutonium-240 and plutonium-241 in environmental samples using low-level liquid scintillation spectrometryThe Analyst, 1992
- Determination of some antioxidants by derivative spectrophotometric method and high-performance liquid chromatographyAnalytical Letters, 1990
- Versatile automatic stopped-flow system for routine analysisAnalytica Chimica Acta, 1987
- High-performance liquid chromatographic determination of antioxidants in fats and oilsJournal of Chromatography A, 1987
- Analytical chemistry of synthetic food antioxidants. A reviewThe Analyst, 1987
- Flow injection spectrofluorimetric determination of europium(III) based on solubilising its ternary complex with thenoyltrifluoroacetone and trioctylphosphine oxide in micellar solutionThe Analyst, 1986
- Spectrophotometric determination of some antioxidants with potassium permanganate and metolFood Chemistry, 1985