Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Top Cited Papers
- 8 March 2007
- journal article
- research article
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 356 (10), 998-1008
- https://doi.org/10.1056/nejmoa067193
Abstract
The safety of drug-eluting stents has been called into question by recent reports of increased stent thrombosis, myocardial infarction, and death. Such studies have been inconclusive because of their insufficient size, the use of historical controls, a limited duration of follow-up, and a lack of access to original source data. We performed a pooled analysis of data from four double-blind trials in which 1748 patients were randomly assigned to receive either sirolimus-eluting stents or bare-metal stents and five double-blind trials in which 3513 patients were randomly assigned to receive either paclitaxel-eluting stents or bare-metal stents; we then analyzed the major clinical end points of the trials. The 4-year rates of stent thrombosis were 1.2% in the sirolimus-stent group versus 0.6% in the bare-metal–stent group (P=0.20) and 1.3% in the paclitaxel-stent group versus 0.9% in the bare-metal–stent group (P=0.30). However, after 1 year, there were five episodes of stent thrombosis in patients with sirolimus-eluting stents versus none in patients with bare-metal stents (P=0.025) and nine episodes in patients with paclitaxel-eluting stents versus two in patients with bare-metal stents (P=0.028). The 4-year rates of target-lesion revascularization were markedly reduced in both the sirolimus-stent group and the paclitaxel-stent group, as compared with the bare-metal–stent groups. The rates of death or myocardial infarction did not differ significantly between the groups with drug-eluting stents and those with bare-metal stents. Stent thrombosis after 1 year was more common with both sirolimus-eluting stents and paclitaxel-eluting stents than with bare-metal stents. Both drug-eluting stents were associated with a marked reduction in target-lesion revascularization. There were no significant differences in the cumulative rates of death or myocardial infarction at 4 years.Keywords
This publication has 26 references indexed in Scilit:
- Clinical Efficacy of Polymer-Based Paclitaxel-Eluting Stents in the Treatment of Complex, Long Coronary Artery Lesions From a Multicenter, Randomized TrialCirculation, 2005
- Comparison of a Polymer-Based Paclitaxel-Eluting Stent With a Bare Metal Stent in Patients With Complex Coronary Artery DiseaseJAMA, 2005
- The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS)Journal of the American College of Cardiology, 2004
- A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS)The Lancet, 2003
- Randomized Study to Assess the Effectiveness of Slow- and Moderate-Release Polymer-Based Paclitaxel-Eluting Stents for Coronary Artery LesionsCirculation, 2003
- Sirolimus-Eluting Stent Implanted in Human Coronary Artery for 16 MonthsCirculation, 2003
- TAXUS ICirculation, 2003
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002