Measurement of the Interstitial Pressure in Subcutaneous Tissue in Dogs
- 1 June 1970
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 26 (6), 765-770
- https://doi.org/10.1161/01.res.26.6.765
Abstract
A probe consisting of a cotton thread fitted inside a 15-cm Teflon tube with an inner diameter of 0.8 mm and connected to a transducer was used to measure the interstitial pressure in the subcutaneous tissue in six anesthetized dogs. The measurements were reproducible with a standard deviation of ±0.64 mm Hg. In six dogs the mean pressure in the subcutaneous tissue of the thorax was --2.74 mm Hg (range --3.25 to --1.99 mm Hg). After hemorrhage and dextran (10%) infusion, the mean pressure decreased by 1.70 mm Hg. After infusion of lactated Ringer's solution, the pressure increased to the control values.Keywords
This publication has 7 references indexed in Scilit:
- Interstitial fluid pressure in terrestrial and semiterrestrial animals.Journal of Applied Physiology, 1969
- Negative Pressure in the Interstitial Fluid of AnimalsScience, 1968
- HemodynamicsAnnual Review of Physiology, 1968
- The use of I131 albumin tissue clearance measurements and other physiological tests for the clinical assessment of patients with lymphœdemaBritish Journal of Plastic Surgery, 1967
- An Indirect Method for Estimating Tissue Pressure with Special Reference to Tissue Pressure in Muscle during Exercise1Acta Physiologica Scandinavica, 1964
- Measurement of Blood Volume with a New ApparatusNew England Journal of Medicine, 1961