Computerized videokeratography and keratometry in determining intraocular lens calculations
- 1 April 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 22 (3), 362-366
- https://doi.org/10.1016/s0886-3350(96)80251-3
Abstract
Purpose: To compare the accuracy of standard keratometry and computerized videokeratography (CVK) in determining intraocular lens (IOL) power calculations. Methods: Using the EyeSys Corneal Analysis SystemTM, we prospectively obtained CVK maps on 75 eyes of 69 patients scheduled to have phacoemulsification with implantation of a posterior chamber intraocular lens. Using manifest refraction obtained at 6 weeks postoperatively, we optimized the calculations for the Hoffer Q, Holladay, and SRK/T formulas for standard keratometric and the following six CVK values: average curvatures at the 1 mm, 2 mm, and 3 mm zones, the keratometric equivalent at the 3 mm zone, and the Stiles-Crawford weighted averages over the 3 mm and 6 mm zones. The accuracy of these parameters was determined by calculating the mean absolute error and percentage of patients with accuracy within ≤ 0.5 diopter (D), ≤ 1.0 D, and ≤ 2.0 D. Results: Keratometrically derived data were slightly more accurate than the CVK-derived values. The average difference in mean absolute error between the keratometric and CVK values was 0.13 D for the Hoffer Q formula, 0.11 D for the Holladay, and 0.08 D for the SRK/T. Conclusions: In this population of patients, we found the CVK-derived corneal curvature values to be slightly less accurate than standard keratometry in predicting IOL power. However, CVK provides important corneal curvature data for IOL calculations in patients with abnormal or surgically altered corneal surfaces.Keywords
This publication has 11 references indexed in Scilit:
- Applications of Computerized Videokeratography in the Management of Cataract Surgical PatientsSeminars in Ophthalmology, 1994
- The Hoffer Q formula: A comparison of theoretic and regression formulasJournal of Cataract & Refractive Surgery, 1993
- Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculationsJournal of Cataract & Refractive Surgery, 1993
- Comparison of the accuracy and reproducibility of the keratometer and the EyeSys Corneal Analysis System Model IJournal of Cataract & Refractive Surgery, 1992
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 1992
- Development of the SRK/T intraocular lens implant power calculation formulaJournal of Cataract & Refractive Surgery, 1990
- Refractive Complications of Cataract Surgery After Radial KeratotomyAmerican Journal of Ophthalmology, 1989
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- Corneal ModelingCornea, 1988
- On the Stiles-Crawford EffectJournal of the Optical Society of America, 1944