Visualization of the Retinal Image in an Eye Model With Spherical and Aspheric, Diffractive, and Refractive Multifocal Intraocular Lenses
- 1 March 2008
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 24 (3), 223-232
- https://doi.org/10.3928/1081597x-20080301-03
Abstract
Purpose: To present a method that visually demonstrates how spherical, aspheric, diffractive, and refractive multifocal intraocular lenses (IOLs) process light received from the cornea. Methods: Monochromatic green light was projected through an Average Cornea Eye (ACE) Model with a cornea in front of the IOL. The model simulates a human cornea with average spherical aberration and visualizes the converging bundle of light leaving the IOL. Additionally, a US Air Force target was projected through the model, and the projected (retinal) image was captured. Various IOLs of differing designs were evaluated using this test setup. Multifocal IOLs included the aspheric diffractive Tecnis ZM900 and ZMA00 lenses; the refractive ReZoom NXG1 lens; the spherical AcrySof ReSTOR SA60D3 apodized diffractive lens; and the spherical diffractive CeeOn 811E lens. Monofocal IOLs included the spherical CeeOnEdge 911A IOL and the aspheric SofPort LI61AO, AcrySof IQ SN60WF, and Tecnis Z9000 and ZA9003 IOLs. Results: The light paths of the different diffractive and refractive multifocal IOLs showed the variations in the processing of incoming light, illustrating the functional differences of IOL concepts. The US Air Force target projections in the ACE Model gave an impression of the functional optical quality of the different lenses. The value of this visualization method was demonstrated by comparing the results with modulation transfer function measurements. Conclusions: This visualization technique furthers the understanding of the working principles and quality of the retinal images produced by different mono- and multifocal IOLs. [ J Refract Surg . 2008;24:223–232.]Keywords
This publication has 26 references indexed in Scilit:
- Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyesJournal of Cataract & Refractive Surgery, 2007
- Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Reading ability with 3 multifocal intraocular lens modelsJournal of Cataract & Refractive Surgery, 2006
- Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Visual Performance of AcrySof ReSTOR Apodized Diffractive IOL: A Prospective Comparative TrialAmerican Journal of Ophthalmology, 2006
- History and development of the apodized diffractive intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameterJournal of Cataract & Refractive Surgery, 2006
- Optical performance of 3 intraocular lens designs in the presence of decentrationJournal of Cataract & Refractive Surgery, 2005
- Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Were ImplantedArchives of Ophthalmology (1950), 2002
- Quantitative Performance of Bifocal and Multifocal Intraocular Lenses in a Model EyeArchives of Ophthalmology (1950), 2002