The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull
Top Cited Papers
- 21 May 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 82A (1), 169-178
- https://doi.org/10.1002/jbm.a.31138
Abstract
The influence of tethering silicon microelectrode arrays on the cortical brain tissue reaction was compared with that of untethered implants placed in the same location by identical means using immunoflourescent methods and cell type specific markers over indwelling periods of 1–4 weeks. Compared with untethered, freely floating implants, tethered microelectrodes elicited significantly greater reactivity to antibodies against ED1 and GFAP over time. Regardless of implantation method or indwelling time, retrieved microelectrodes contained a layer of attached macrophages identified by positive immunoreactivity against ED1. In the tethered condition and in cases where the tissue surrounding untethered implants had the highest levels of ED1+ and GFAP+ immunoreactivity, the neuronal markers for neurofilament 160 and NeuN were reduced. Although the precise mechanisms are unclear, the present study indicates that simply tethering silicon microelectrode arrays to the skull increases the cortical brain tissue response in the recording zone immediately surrounding the microelectrode array, which signals the importance of identifying this important variable when evaluating the tissue response of different device designs, and suggests that untethered or wireless devices may elicit less of a foreign body response. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007Keywords
This publication has 35 references indexed in Scilit:
- Multielectrode recordings: the next stepsCurrent Opinion in Neurobiology, 2002
- Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length MicroelectrodesJournal of Neurophysiology, 2001
- Stability of the interface between neural tissue and chronically implanted intracortical microelectrodesIEEE Transactions on Rehabilitation Engineering, 1999
- Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus as a treatment of movement disordersJournal of Neurosurgery, 1996
- Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleusThe Lancet, 1991
- Performance of planar multisite microprobes in recording extracellular single-unit intracortical activityIEEE Transactions on Biomedical Engineering, 1988
- Histopathologic evaluation of prolonged intracortical electrical stimulationExperimental Neurology, 1986
- Simultaneous individual recordings from many cerebral neurons: Techniques and resultsReviews of physiology, biochemistry and pharmacology, 1983
- The ultrastructure of the sheath around chronically implanted electrodes in brainJournal of Neurocytology, 1976
- Long-term chronic recording from cortical neuronsExperimental Neurology, 1976