Timolol in aqueous humour after topical administration
- 1 August 1985
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 63 (4), 415-417
- https://doi.org/10.1111/j.1755-3768.1985.tb01555.x
Abstract
The concentration of timolol in aqueous humour after one single drop of timolol ophthalmic solution was studied in 19 patients. Relatively high concentrations were found (mean: 626 ng/ml), but the individual differences were greater (range: 0 ng/ml - 2080 ng/ml). Possible explanations are discussed. No detectable levels of timolol were found in plasma (detection level .gtoreq. 1 ng/ml).Keywords
This publication has 11 references indexed in Scilit:
- ADDITIVE INTRAOCULAR PRESSURE REDUCING EFFECT OF TOPICAL TIMOLOL DURING SYSTEMIC β‐BLOCKADEActa Ophthalmologica, 1982
- Penetration of timolol eye drops into human aqueous humour.British Journal of Ophthalmology, 1981
- Studies of action mechanism of antiglaucoma drugs with a newly developed cat modelLife Sciences, 1980
- Absorption of Ocular Timolol1Clinical Pharmacokinetics, 1980
- Interaction of Topical and Oral Timolol in GlaucomaOphthalmology, 1979
- The Mechanism of Timolol in Lowering Intraocular PressureArchives of Ophthalmology (1950), 1978
- A fluorophotometric study of the effect of topical timolol on aqueous humor dynamicsExperimental Eye Research, 1978
- TimololArchives of Ophthalmology (1950), 1977
- INTRAOCULAR-PRESSURE DECREASE IN NORMAL VOLUNTEERS FOLLOWING TIMOLOL OPHTHALMIC SOLUTION1976