Complementary Clinical Benefits of Coronary-Artery Stenting and Blockade of Platelet Glycoprotein IIb/IIIa Receptors
Open Access
- 29 July 1999
- journal article
- clinical trial
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 341 (5), 319-327
- https://doi.org/10.1056/nejm199907293410503
Abstract
Inhibition of the platelet glycoprotein IIb/IIIa receptor with the monoclonal-antibody fragment abciximab reduces the acute ischemic complications associated with percutaneous coronary revascularization, whereas coronary-stent implantation reduces restenosis. We conducted a trial to determine the efficacy of abciximab and stent implantation in improving long-term outcome. A total of 2399 patients were randomly assigned to stent implantation and placebo, stent implantation and abciximab, or balloon angioplasty and abciximab. The patients were followed for six months. At six months, the incidence of the composite end point of death or myocardial infarction was 11.4 percent in the group that received a stent and placebo, as compared with 5.6 percent in the group that received a stent and abciximab (hazard ratio, 0.47; 95 percent confidence interval, 0.33 to 0.68; P<0.001) and 7.8 percent in the group assigned to balloon angioplasty and abciximab (hazard ratio, 0.67; 95 percent confidence interval, 0.49 to 0.92; P=0.01). The hazard ratio for stenting plus abciximab as compared with angioplasty plus abciximab was 0.70 (95 percent confidence interval, 0.48 to 1.04; P=0.07). The rate of repeated revascularization of the target vessel was 10.6 percent in the stent-plus-placebo group, as compared with 8.7 percent in the stent-plus-abciximab group (hazard ratio, 0.82; 95 percent confidence interval, 0.59 to 1.13; P=0.22) and 15.4 percent in the angioplasty-plus-abciximab group (hazard ratio, 1.49; 95 percent confidence interval, 1.13 to 1.97; P=0.005). The hazard ratio for stenting plus abciximab as compared with angioplasty plus abciximab was 0.55 (95 percent confidence interval, 0.41 to 0.74; P<0.001). Among patients with diabetes, the combination of abciximab and stenting was associated with a lower rate of repeated target-vessel revascularization (8.1 percent) than was stenting and placebo (16.6 percent, P=0.02) or angioplasty and abciximab (18.4 percent, P=0.008). For coronary revascularization, abciximab and stent implantation confer complementary long-term clinical benefits.Keywords
This publication has 17 references indexed in Scilit:
- Coronary-Artery Stenting Compared with Balloon Angioplasty for Restenosis after Initial Balloon AngioplastyNew England Journal of Medicine, 1998
- Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)The Lancet, 1998
- Randomised placebo-controlled and balloon-angioplasty-controlled trial to assess safety of coronary stenting with use of platelet glycoprotein-IIb/IIIa blockadeThe Lancet, 1998
- Platelet Glycoprotein IIb/IIIa Receptor Blockade and Low-Dose Heparin during Percutaneous Coronary RevascularizationNew England Journal of Medicine, 1997
- Randomised placebo-controlled trial of abciximab before and during coronary intervention in refractory unstable angina: the CAPTURE studyThe Lancet, 1997
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- Randomised trial of coronary intervention with antibody against platelet IIb/IIIa iritegrin for reduction of clinical restenosis: results at six monthsThe Lancet, 1994
- Use of a Monoclonal Antibody Directed against the Platelet Glycoprotein IIb/IIIa Receptor in High-Risk Coronary AngioplastyNew England Journal of Medicine, 1994
- Automated quantitative coronary arteriography: morphologic and physiologic validation in vivo of a rapid digital angiographic method.Circulation, 1987