Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study
- 23 July 2015
- journal article
- Published by Springer Nature in European Radiology
- Vol. 26 (4), 979-985
- https://doi.org/10.1007/s00330-015-3924-8
Abstract
To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. The number of CT examinations during pregnancy increased from 3–4 per year in 2008–2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7–60.5 mGy). The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. • An increase in CT imaging of pregnant patients is of concern. • Clinical indications were in line with good practice. • Estimated conceptus doses were lower or similar to published data. • Internal guidelines for appropriate use of imaging during pregnancy should be established.Keywords
This publication has 22 references indexed in Scilit:
- Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantomsRadiation Protection Dosimetry, 2012
- Fetal Risk in Diagnostic RadiologySeminars in Ultrasound, CT and MRI, 2012
- Compendium of National Guidelines for Imaging the Pregnant PatientAmerican Journal of Roentgenology, 2011
- The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulationsPhysics in Medicine & Biology, 2009
- Radiation Dose to the Fetus for Pregnant Patients Undergoing Multidetector CT Imaging: Monte Carlo Simulations Estimating Fetal Dose for a Range of Gestational Age and Patient SizeRadiology, 2008
- Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current ModulationAmerican Journal of Roentgenology, 2008
- Investigation into the effects of lead shielding for fetal dose reduction in CT pulmonary angiographyThe British Journal of Radiology, 2007
- Contribution of three‐dimensional computed tomography in the assessment of fetal skeletal dysplasiaUltrasound in Obstetrics & Gynecology, 2007
- Estimation of Fetal Radiation Dose from Computed Tomography Scanning in Late PregnancyInvestigative Radiology, 2000
- Effektivität der Bleiabdeckung zur Dosisreduktion beim Patienten in der ComputertomographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996