Blood flow measurement using digital angiography and parametric imaging
- 1 March 1984
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 11 (2), 153-157
- https://doi.org/10.1118/1.595491
Abstract
A method of blood flow measurement is described that determines flow through a particular artery in absolute units or as a fraction of the cardiac output. For measuring flow as a percentage of cardiac output, no assumption about the vessel''s cross-sectional shape is necessary. If it is assumed that the vessel''s cross section is circular, then absolute flow determination is possible. All methods would require only a single i.v. injection of contrast material. Details of the theory of these methods are presented and alternative data analysis options are developed and discussed.This publication has 10 references indexed in Scilit:
- USE OF FUNCTIONAL MAPS IN RENAL SCINTIGRAPHY TO DETECT SEGMENTAL ARTERIAL LESIONS1982
- A METHOD FOR OBJECTIVE EVALUATION OF FUNCTIONAL IMAGES1982
- Regional distribution of cardiac output: normal values in man determined by video dilution techniqueAmerican Journal of Roentgenology, 1981
- Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devicesMedical Physics, 1981
- Determination of cerebral blood flow with the EMI CT scannerThe British Journal of Radiology, 1980
- Clinical cerebral blood flow measurement with inhaled xenon and CTAmerican Journal of Roentgenology, 1980
- Computerized Fluoroscopy in Real Time for Noninvasive Visualization of the Cardiovascular SystemRadiology, 1979
- An intravenous isotope method for measuring regional cerebral blood flow (rCBF) and volume (rCBV)Physics in Medicine & Biology, 1977
- Indicator Transit Time Considered as a Gamma VariateCirculation Research, 1964
- Theoretical Basis of Indicator-Dilution Methods For Measuring Flow and VolumeCirculation Research, 1962