Difference in bone ingrowth after one versus two daily episodes of micromotion: Experiments with titanium chambers in rabbits
- 1 November 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (11), 1419-1424
- https://doi.org/10.1002/jbm.820271109
Abstract
Mechanical stimulation has been shown to affect the differentiation and development of mesenchymal tissue. In the present study, we compared the histological and histomorphometric results of tissue ingrowth into micromotion chambers that were moved at 0 cycles per day, 20 cycles once per day, and 20 cycles twice per day over 20–30 sec, for 3 weeks. In each case, a chamber having a 1 × 1 × 5 mm square‐holed groove for tissue ingrowth was used. The total amplitude of motion was 0.75 mm. Histological sections from nonmoved chambers contained extensive trabecular bone, embedded in a fibrovascular stroma. Histomorphometric analysis disclosed that bone comprised a mean of 31 ± 2% (mean ± SEM) of the ingrown tissue. Twenty movements per day appeared to further stimulate bone ingrowth (46 ± 5%). Extensive ingrowth of more immature woven and trabecular bone was noted in a more cellular stroma. In general, increasing the degree of micromotion to 20 movements twice per day resulted in a decreased amount of bone formation (19 ± 7%). In several of these specimens, little or no bone could be found. These experiments have demonstrated that, for the parameters chosen in this study, a short daily period of low frequency, micromotion may facilitate bone ingrowth; however, when the same motion is delivered twice daily, bone ingrowth is depressed. Thus a “window” of externally applied strain appears to exist, which may facilitate or discourage tissue differentiation to bone. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 17 references indexed in Scilit:
- Ingrowth of bone into pores in titanium chambers implanted in rabbits: Effect of pore cross‐sectional shape in the presence of dynamic shearJournal of Biomedical Materials Research, 1993
- Effect of amplitude of micromotion on bone ingrowth into titanium chambers implanted in the rabbit tibiaBiomaterials, 1992
- Intermittent micromotion inhibits bone ingrowthActa Orthopaedica, 1992
- Musculoskeletal ontogeny, phylogeny, and functional adaptationJournal of Biomechanics, 1991
- Functional strains and cortical bone adaptation: Epigenetic assurance of skeletal integrityJournal of Biomechanics, 1990
- Adaptive bone-remodeling theory applied to prosthetic-design analysisJournal of Biomechanics, 1987
- Mechanical loading history and skeletal biologyJournal of Biomechanics, 1987
- Functional strain in bone tissue as an objective, and controlling stimulus for adaptive bone remodellingJournal of Biomechanics, 1987
- Regulation of bone mass by mechanical strain magnitudeCalcified Tissue International, 1985
- Dynamic strain similarity in vertebrates; an alternative to allometric limb bone scalingJournal of Theoretical Biology, 1984