Radiation characteristics of helical tomotherapy
Open Access
- 27 January 2004
- journal article
- Published by Wiley in Medical Physics
- Vol. 31 (2), 396-404
- https://doi.org/10.1118/1.1639148
Abstract
Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent optimized for intensity modulated delivery.Keywords
This publication has 30 references indexed in Scilit:
- Using Monte Carlo methods to commission electron beams: A feasibility studyMedical Physics, 2002
- Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX acceleratorPhysics in Medicine & Biology, 2002
- The effect of scattering foil parameters on electron‐beam Monte Carlo calculationsMedical Physics, 2001
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- Photon beam characterization and modelling for Monte Carlo treatment planningPhysics in Medicine & Biology, 2000
- Electron beam modeling and commissioning for Monte Carlo treatment planningMedical Physics, 2000
- The flatness of Siemens linear accelerator x‐ray fieldsMedical Physics, 1999
- Monte Carlo calculations of electron beam output factors for a medical linear acceleratorPhysics in Medicine & Biology, 1998
- A Monte Carlo study of accelerator head scatterMedical Physics, 1994
- Monte Carlo simulation of a cobalt‐60 beamMedical Physics, 1987