Validity of physical activity monitors in adults participating in free-living activities
- 15 July 2008
- journal article
- research article
- Published by BMJ in British Journal of Sports Medicine
- Vol. 44 (9), 657-664
- https://doi.org/10.1136/bjsm.2008.048868
Abstract
Background For a given subject, time in moderate to very vigorous intensity physical activity (MVPA) varies substantially among physical activity monitors. Objective In the present study, the primary objective, whether time in MVPA recorded with SenseWear Pro2 Armband (Armband; BodyMedia, Pittsburgh, Pennsylvania, USA), ActiGraph (7164, LLC, Fort Walton Beach, Florida, USA), ikcal (Teltronic AG, Biberist, Switzerland) and ActiReg (PreMed AS, Oslo, Norway) is different compared with indirect calorimetry, was determined. The secondary objective, whether these activity monitors estimate energy expenditure differently compared with indirect calorimetry, was also determined. Material and methods The activity monitors and a portable oxygen analyser were worn by 14 men and 6 women for 120 min doing a variety of activities of different intensities. Resting metabolic rate was measured with indirect calorimetry. The cutoff points defining moderate, vigorous and very vigorous intensity were three, six and nine times resting metabolic rate. Results Time in MVPA was overestimated by 2.9% and 2.5% by Armband and ActiGraph, respectively, and was underestimated by 11.6% and 98.7% by ikcal and ActiReg, respectively. ActiReg (p = 0.004) and ActiGraph (p = 0.007) underestimated energy expenditure in MVPA, and all monitors underestimated total energy expenditure (by 5% to 21%). Conclusions Recorded time in MVPA and energy expenditure varies substantially among physical activity monitors. Thus, when comparing physical activity level among studies, it is essential to know the type of physical activity monitor being used.Keywords
This publication has 27 references indexed in Scilit:
- Evaluation of a portable device to measure daily energy expenditure in free-living adultsThe American Journal of Clinical Nutrition, 2007
- Estimating energy expenditure using accelerometersEuropean Journal of Applied Physiology, 2006
- Best Practice Methods to Apply to Measurement of Resting Metabolic Rate in Adults: A Systematic ReviewJournal of the American Dietetic Association, 2006
- Description and validation of the ActiReg®: a novel instrument to measure physical activity and energy expenditureBritish Journal of Nutrition, 2004
- America’s obesity epidemic: Measuring physical activity to promote an active lifestyleJournal of the American Dietetic Association, 2004
- Validation of the MetaMax II Portable Metabolic Measurement SystemInternational Journal of Sports Medicine, 2004
- Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical ActivityInternational Journal of Sports Medicine, 2003
- Examination of the Metamax I and II oxygen analysers during exercise studies in the laboratoryScandinavian Journal of Clinical and Laboratory Investigation, 2002
- Calibration of the Computer Science and Applications, Inc. accelerometerMedicine & Science in Sports & Exercise, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986