A new hydrogel intraocular lens design
- 1 January 1994
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 20 (1), 18-25
- https://doi.org/10.1016/s0886-3350(13)80038-7
Abstract
A new hydrogel intraocular lens was designed to improve fixation and support. The lens, IOGEL model 2000S, has a 6.00 mm optic that merges via a crescentic flange into a terminal loop for an overall diameter of 12.00 mm. The haptics are more flexible than existing loops and the design of the lens is based on a concept of minimum loop rigidity; that is, a haptic that is rigid enough to support the weight of a lens in aqueous within the capsular bag is considered adequate for modern cataract surgery. I evaluated the lens design's safety and efficacy. Excluding patients with pre-existing macular degeneration, the corrected acuity of all patients at last follow-up was 20/40 or better in 100%, 20/30 or better in 95%, 20/25 to 20/20 or better in 85%, and 20/15 or better in 15%. The new haptic can accommodate compression of the capsular bag and allows early, reliable fixation. The centration of the lens was excellent early in the postoperative period and later after capsular fibrosis developed.Keywords
This publication has 15 references indexed in Scilit:
- Exchange of IOGEL hydrogel one-piece foldable intraocular lens for bag-fixated J-loop poly(methyl methacrylate) intraocular lensJournal of Cataract & Refractive Surgery, 1993
- Assessment of the blood-aqueous barrier by fluorophotometry following poly(methyl methacrylate), silicone, and hydrogel lens implantation in rabbit eyesJournal of Cataract & Refractive Surgery, 1993
- Optical performance of decentered monofocal intraocular lensesJournal of Cataract & Refractive Surgery, 1992
- Evaluation of 200 consecutive IOGEL 1103 capsular-bag lenses implanted through a small incisionJournal of Cataract & Refractive Surgery, 1992
- Compatibility of intraocular lenses with blood and connective tissue cells measured by cellular deposition and inflammatory response in vitroJournal of Cataract & Refractive Surgery, 1992
- Optical design of low index intraocular lensesJournal of Cataract & Refractive Surgery, 1991
- Displacement of bag-placed hydrogel lenses into the vitreous following neodymium:YAG laser capsulotomyJournal of Cataract & Refractive Surgery, 1990
- Comparison of the unwanted optical images produced by 6 mm and 7 mm intraocular lensesJournal of Cataract & Refractive Surgery, 1989
- Induced astigmatism in small incision cataract surgeryJournal of Cataract & Refractive Surgery, 1989
- Multicenter trial of an intraocular hydrogel lens implantJournal of Cataract & Refractive Surgery, 1987