Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Top Cited Papers
- 21 April 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (3), 489-506
- https://doi.org/10.1109/tuffc.2009.1067
Abstract
The emergence of ultrafast frame rates in ultrasonic imaging has been recently made possible by the development of new imaging modalities such as transient elastography. Data acquisition rates reaching more than thousands of images per second enable the real-time visualization of shear mechanical waves propagating in biological tissues, which convey information about local viscoelastic properties of tissues. The first proposed approach for reaching such ultrafast frame rates consists of transmitting plane waves into the medium. However, because the beamforming process is then restricted to the receive mode, the echographic images obtained in the ultrafast mode suffer from a low quality in terms of resolution and contrast and affect the robustness of the transient elastography mode. It is here proposed to improve the beamforming process by using a coherent recombination of compounded plane-wave transmissions to recover high-quality echographic images without degrading the high frame rate capabilities. A theoretical model is derived for the comparison between the proposed method and the conventional B-mode imaging in terms of contrast, signal-to-noise ratio, and resolution. Our model predicts that a significantly smaller number of insonifications, 10 times lower, is sufficient to reach an image quality comparable to conventional B-mode. Theoretical predictions are confirmed by in vitro experiments performed in tissue-mimicking phantoms. Such results raise the appeal of coherent compounds for use with standard imaging modes such as B-mode or color flow. Moreover, in the context of transient elastography, ultrafast frame rates can be preserved while increasing the image quality compared with flat insonifications. Improvements on the transient elastography mode are presented and discussed.Keywords
This publication has 27 references indexed in Scilit:
- Extended high-frame rate imaging method with limited-diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2006
- Supersonic shear imaging: a new technique for soft tissue elasticity mappingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2004
- Sonic boom in soft materials: The elastic Cerenkov effectApplied Physics Letters, 2004
- Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibilityJapanese Journal of Clinical Oncology, 2002
- Ultrasound-Stimulated Vibro-Acoustic SpectrographyScience, 1998
- Experimental study of high frame rate imaging with limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1998
- 2D and 3D high frame rate imaging with limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Experimental verification of nondiffracting X wavesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- Pulse-echo imaging using a nondiffracting beam transducerJapanese Journal of Clinical Oncology, 1991
- Ultrasonic nondiffracting transducer for medical imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1990