Time-Resolved 3D Pulmonary Perfusion MRI
- 1 September 2009
- journal article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 44 (9), 525-531
- https://doi.org/10.1097/rli.0b013e3181b4c252
Abstract
Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field strengths. At 1.5 T the peak signal-to-noise ratio of the ERS was significantly lower in comparison to the IRS and the VS technique (14.6 vs. 26.7 and 39.6 respectively, P < 0.004). Using the IRS sampling algorithm comparable image quality and SNR can be achieved at 1.5 and 3 T. At 1.5 T VS offers the best possible solution for the conflicting requirements between a further increased temporal resolution and image quality. In consequence the gain of increased scanning efficiency from advanced k[r]-space sampling acquisition techniques can be exploited for a further improvement of image quality of pulmonary perfusion MRI.Keywords
This publication has 24 references indexed in Scilit:
- Assessment of Differential Pulmonary Blood Flow Using Perfusion Magnetic Resonance ImagingInvestigative Radiology, 2006
- Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis—initial resultsEuropean Radiology, 2006
- Pulmonary Arterial Hypertension: Diagnosis with Fast Perfusion MR Imaging and High-Spatial-Resolution MR Angiography—Preliminary ExperienceRadiology, 2005
- Quantification of Pulmonary Blood Flow and Volume in Healthy Volunteers by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Parallel Imaging TechniqueInvestigative Radiology, 2004
- Contrast-Enhanced Three-Dimensional Pulmonary Perfusion Magnetic Resonance ImagingInvestigative Radiology, 2004
- Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE)Journal of Magnetic Resonance Imaging, 2003
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Pulmonary perfusion: Qualitative assessment with dynamic contrast‐enhanced MRI using ultra‐short TE and inversion recovery turbo FLASHMagnetic Resonance in Medicine, 1996
- Value of the Ventilation/Perfusion Scan in Acute Pulmonary EmbolismJAMA, 1990
- Clinical ventilation-perfusion scintigraphyClinical Physiology and Functional Imaging, 1981