Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging
Top Cited Papers
- 9 August 2005
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (3), 636-644
- https://doi.org/10.1002/mrm.20624
Abstract
Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2pi/3, with the middle echo centered at pi/2+pik (k=any integer), i.e., (-pi/6+pik, pi/2+pik, 7pi/6+pik). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.Keywords
This publication has 26 references indexed in Scilit:
- Cramér–Rao bounds for three‐point decomposition of water and fatMagnetic Resonance in Medicine, 2005
- Multicoil Dixon chemical species separation with an iterative least‐squares estimation methodMagnetic Resonance in Medicine, 2003
- Fat‐suppressed steady‐state free precession imaging using phase detectionMagnetic Resonance in Medicine, 2003
- Is TrueFISP a gradient‐echo or a spin‐echo sequence?Magnetic Resonance in Medicine, 2003
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon techniqueJournal of Magnetic Resonance Imaging, 1995
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990
- Resolution of NMR chemical shift images into real and imaginary componentsPhysics in Medicine & Biology, 1986