Modeling the effects of dispersion and pulsatility of blood flow in pulsed arterial spin labeling
Open Access
- 25 June 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (1), 53-63
- https://doi.org/10.1002/mrm.21654
Abstract
Arterial spin labeling (ASL) is a method of using MRI to image cerebral perfusion. For the measurement to be calibrated, a model is required describing the kinetics of the flow of the inverted blood from the labeling region to the imaging region. It is common to assume plug-flow, but alternatives such as a Gaussian distribution of arrival times have also been suggested. In this study a physiologically based model for dispersion is developed and compared to existing models when fit to experimental data. The model is based on the assumption of parabolic flow in the major arteries, and also allows inclusion of cardiac pulsatility. It was found that fitting using the proposed model leads to higher perfusion estimates, with the difference becoming more pronounced in regions where the dispersion is greater. This suggests that current models may underestimate perfusion in these areas. However, fitting using the proposed model also leads to high uncertainties in parameter estimates due to non-orthogonality of the parameters. Effects due to pulsatility are expected to be observable, but when no cardiac-gating is used the mean curve over several cardiac cycles is predicted to closely match the curve which assumes constant flow. Magn Reson Med 60:53–63, 2008.Keywords
This publication has 19 references indexed in Scilit:
- Model‐free arterial spin labeling quantification approach for perfusion MRIMagnetic Resonance in Medicine, 2006
- Quantitative perfusion measurements using pulsed arterial spin labeling: Effects of large region‐of‐interest analysisJournal of Magnetic Resonance Imaging, 2005
- Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteriesPhysiological Measurement, 2005
- Two analytical solutions for a model of pulsed arterial spin labeling with randomized blood arrival timesJournal of Magnetic Resonance, 2004
- Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 TeslaMagnetic Resonance in Medicine, 2003
- Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniquesMagnetic Resonance in Medicine, 1997
- Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopyMagnetic Resonance in Medicine, 1996
- Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water.Proceedings of the National Academy of Sciences, 1994
- Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proceedings of the National Academy of Sciences, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992