Comparison of Late Luminal Loss Response Pattern After Sirolimus-Eluting Stent Implantation or Conventional Stenting
- 16 November 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 110 (20), 3199-3205
- https://doi.org/10.1161/01.cir.0000147275.50550.68
Abstract
Background— We investigated the pattern of late luminal loss after sirolimus-eluting or bare stent implantation. Methods and Results— The study population comprised 238 patients treated with sirolimus-eluting stents and 526 patients treated with conventional stents. The distribution of late loss of sirolimus stents was largely skewed to the right and differed from the distribution for bare stents. When divided according to the presence of binary restenosis (diameter stenosis >50%), restenotic lesions in the bare stent group (26.0%) had a late loss of 1.40±0.64 mm and in the sirolimus group (7.9%) of 1.16±0.76 mm. Nonrestenotic lesions in the bare stent group had a late loss of 0.58±0.44 mm, whereas the late loss of nonrestenotic lesions in the sirolimus group remained close to zero (−0.05±0.33 mm). Differences between poststenting and follow-up measurements in the sirolimus group (late loss) resembled variations observed in repeated angiographic measurements, as assessed from a random sample of 30 segments measured repeatedly. After multivariate adjustment, stent type did not influence the degree of late loss in restenotic lesions. However, nonrestenotic bare stents had a significantly larger estimated luminal loss (0.58 mm; 95% CI, 0.52 to 0.65) than sirolimus-eluting stents, for which the predicted late loss was almost 0 (−0.04 mm; 95% CI, −0.10 to 0.02). Conclusions— The pattern of late loss after sirolimus-eluting stent implantation follows a peculiar behavior, different from lesions treated with conventional stents. Whether this is explained by an unusual statistical distribution or a biological all-or-none response of restenosis after sirolimus-eluting stenting remains to be investigated.Keywords
This publication has 13 references indexed in Scilit:
- Clinical, Angiographic, and Procedural Predictors of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Complex PatientsCirculation, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Coronary Restenosis After Sirolimus-Eluting Stent ImplantationCirculation, 2003
- Preliminary Observations Regarding Angiographic Pattern of Restenosis After Rapamycin-Eluting Stent ImplantationCirculation, 2003
- Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)Circulation, 2002
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002
- Long-Term Treatment with a Platelet Glycoprotein-Receptor Antagonist after Percutaneous Coronary RevascularizationNew England Journal of Medicine, 2000
- Restenosis revisited: Insights provided by quantitative coronary angiographyAmerican Heart Journal, 1993
- Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: Failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilationJournal of the American College of Cardiology, 1988
- Restenosis after percutaneous transluminal coronary angioplasty: The emory university hospital experienceThe American Journal of Cardiology, 1987