Matrix‐assisted laser desorption using a fast‐atom bombardment ion source and a magnetic mass spectrometer
- 1 April 1992
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 6 (4), 298-302
- https://doi.org/10.1002/rcm.1290060415
Abstract
A conventional fast‐atom bombardment (FAB) ion source was used to achieve matrix‐assisted laser desorption (MALD) in a high‐mass, double‐focusing, magnetic mass spectrometer. The pulsed ion signals generated by irradiation of a mixture of sample and matrix (2,5‐dihydroxybenzoic acid) with either a XeF excimer Laser (353 nm) or a nitrogen laser (337 nm) were recorded with a focal‐plane detector. A resolution (full‐width at half maximum) of 4500 was achieved at m/z 1347.7 (the peptide substance P), 2500 for CsI cluster ions at m/z 10005.7, and 1250 for the isotope cluster of the small protein cytochrome c (horse) [M+H]+=m/z 12360 (average). Sensitivity is demonstrated with 11 fmol of substance P. A survey scan is taken to prodluce a better signal‐to‐noise ratio. In addition to higher sensitivity and lower matrix interference, lthe advantage of MALD over FAB is the former's lower susceptibility to the presence of salts, and competition between hydrophobic and bydrophilic components of a mixture. This feature is demonstrated by the complete MALD spectrum of a crude partial tryptic digest of spedrm‐whale apomyoglobin, containing 24 peptides, representing the entire sequence of this protein.This publication has 9 references indexed in Scilit:
- Factors affecting the fast atom bombardment mass spectrometric analysis of proteolytic digests of proteinsJournal of Mass Spectrometry, 1992
- A variable dispersion array detector for a tandem mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1991
- 2,5-Dihydroxybenzoic acid: a new matrix for laser desorption—ionization mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Matrix‐assisted laser desorption ionization with a magnetic mass spectrometerRapid Communications in Mass Spectrometry, 1991
- Design considerations, calibration and applications of an array detector for a four-sector tandem mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1989
- Preliminary X-ray Crystallography Studies of Recombinant Human Interleukin-1αPublished by Elsevier ,1989
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- High-performance tandem mass spectrometry: calibration and performance of linked scans of a four-sector instrumentAnalytical Chemistry, 1987
- An approach towards the complete FAB analysis of enzymic digests of peptides and proteinsJournal of the American Chemical Society, 1986