Reliability of Transcutaneous Oximeter Electrode Heating Power During Exercise in Patients with Intermittent Claudication
- 1 March 1997
- journal article
- Published by SAGE Publications in Angiology
- Vol. 48 (3), 229-235
- https://doi.org/10.1177/000331979704800305
Abstract
The purposes of this study were to (1) compare the reliability of transcutaneous oximeter electrode power with the reliability of oxygen tension and (2) compare the relationship of the oximetry measures with exercise performance in claudicants. One hundred ten PAOD patients with stable claudication symptoms performed a treadmill test and had the following exercise measures obtained: foot transcutaneous oxygen tension, oximeter electrode heating power, exercise duration, and peak oxygen consumption. A subset of 30 patients were tested once per week over three successive weeks to assess the reliability of the oximetry measures. The coefficient of variation of foot transcutaneous oxygen tension at peak exercise was 32.8%, whereas the variability of the oximeter electrode heating power was only 5.1%. Oximeter electrode heating power at peak exercise was related to maximal claudication pain time ( r=0.44, P < 0.001) and peak oxygen consumption ( r=0.36, P < 0.001), whereas foot transcutaneous oxygen tension was not related to either ( r=0.15, P=0.119; r=0.13, P=0.189; respectively). Thus, transcuta neous oximeter electrode heating power was six to seven times less variable than tran scutaneous oxygen tension, and the oximeter electrode power at peak exercise was more closely related to exercise capacity. It is concluded that the measurement of transcuta neous oximeter electrode heating power during exercise is more reliable and better corre lated with exercise capacity in PAOD patients with intermittent claudication than the measurement of transcutaneous oxygen tension.Keywords
This publication has 9 references indexed in Scilit:
- Stair Climbing Elicits a Lower Cardiovascular Demand Than Walking in Claudication PatientsJournal of Cardiopulmonary Rehabilitation, 1995
- Claudication Pain and Hemodynamic Responses to Exercise in Younger and Older Peripheral Arterial Disease PatientsJournal of Gerontology, 1993
- Effects of handrail support on claudication and hemodynamic responses to single-stage and progressive treadmill protocols in peripheral vascular occlusive diseaseThe American Journal of Cardiology, 1991
- Transcutaneous oxygen and carbon dioxide pressure monitoring to determine severity of limb ischemia and to predict surgical outcomeJournal of Vascular Surgery, 1988
- The Use of Transcutaneous Oxygen Tension Measurements in the Diagnosis of Peripherial Vascular InsufficiencyAnnals of Surgery, 1984
- Utility of transcutaneous oxygen tension measurements in peripheral arterial occlusive diseaseJournal of Vascular Surgery, 1984
- Noninvasive evaluation of peripheral vascular disease using transcutaneous oxygen tensionThe American Journal of Surgery, 1982
- Dependence of Transcutaneous Oxygen Tension on Local Arteriovenous Pressure Gradient in Normal SubjectsClinical Science, 1981
- Correlation of transcutaneous oxygen tension to blood flow in heated skinScandinavian Journal of Clinical and Laboratory Investigation, 1980